15
H1651 1651 Rev. G
Six Monthly Service (By Owner)
Operate the Pressure and Temperature
Relief Valve for approximately 10
seconds by raising the easing lever on
the top of the valve to ensure water is
able to be relieved through the relief
drain pipe. Check to ensure the valve
closes correctly.
Annual Service (By Authorised
Personnel Only)
Clean and service the gas burner and
pilot.
Five Year Service (By Authorised
Personnel Only)
The ve yearly service should be carried
out by a licensed Tradesperson. It is
recommended that this service be
carried out by your local Dux agent. The
service should include the following:
• Replace the Pressure and
Temperature Relief Valve.
• Replace the anode. In areas of
harsh or adverse water conditions,
it is recommended that you carry
out a more frequent check of your
anode's condition. Refer to “Water
Quality”.
• Clean and service the gas burner
and pilot.
• Flush the cylinder.
Removal And Replacement Of Baf-
e (By Authorised Personnel Only)
There may be some instances where
the bafe may need to be accessed
for cleaning, repairs or replacement. To
access the bafe, the following steps
need to be followed:
• Make sure the gas controller is
turned to pilot or off position before
commencing.
• Remove the plastic lid from the top
of the heater. There are screws at
either side of the lid towards the
rear and a clipping arrangement
at the front which can be popped
using a screwdriver, taking care to
not scratch the heater case.
• Remove the rockwool insulation
blanket. The top of the down duct
will now be present, wrapped in foil-
backed glass insulation.
Caution: Metal surfaces in this
region, including the bafe, may
be hot. Use appropriate protection
when performing the following
procedures.
Service Information