44
RMO40TD DV-Win Software
Start
When START is pressed, the selected results are transferred from the internal RMO40TD memory to the
PC. Unless the user chooses some other option, all the results from the RMO40TD memory will be
After pressing the command transfer, the progress bar is being displayed showing a status of the
transfer.
Stop
pressing this key all the choices are being erased and the user will return back to the main menu.
The results table
The results from internal memory of RMO40TD are transferred to the PC in the data table; the following
layout will be displayed:
Current mode
- Date and Time : the date and the time of the test
- Current : the real test current
- Voltage 1 : the measured voltage on the channel 1 (Ch:1)
- Resistance 1 : the measured resistance on the channel 1 (Ch:1)
- Voltage 2 : the measured voltage on the channel 2 (Ch:2)
- Resistance 2 : the measured resistance on the channel 2 (Ch:2)
- Ripple : the results are zeros
- Memory : the number of the memory location in the RMO40TD where test results are
located
Tap Changer mode
All columns are the same except the following:
- Resistance 1 : the measured resistance (R)
- Ripple : the measured current ripple in percents
- The results in other columns, which are not relevant to the Tap changer mode, are zeros.
After the data is downloaded, you can save it as a PDF, XLS, DOC or RTF file on the hard disk of your
PC.