Dynacraft ultimate spider-man User Manual

Dynacraft ultimate spider-man
26 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #23 background imageLoading...
Page #23 background image
Problem
Short run time
(Less than 15 minutes
per charge)
22
Possible Cause
Tripped thermal fuse
Undercharged battery
Overcharged battery
Battery is old and will not
accept full charge
Tripped thermal fuse
Solution
The built-in thermal fuse may “trip” and shut
down operation of the vehicle if the vehicle
is overloaded or the driving conditions are too
severe. Once a fuse has “tripped”, SET THE
POWER SWITCH TO THE "OFF" POSITION
AND DO NOT CONTINUOUSLY PUSH ON
THE FOOT PEDAL. The fuse will automatically
reset itself after approximately 2 minutes and
allow the vehicle to resume normal operations.
POWER SWITCH TO THE "OFF" POSITION
AND DO NOT CONTINUOUSLY PUSH ON
THE FOOT PEDAL. The fuse will automatically
reset itself after approximately 2 minutes and
allow the vehicle to resume normal operations.
To avoid repeated automatic shutdowns, do
not overload the vehicle by exceeding the 55
Ibs maximum weight capacity or by towing
anything behind the vehicle. Do not drive
up hills or run into fixed objects, which can
cause the wheels to stop spinning while
power is still being supplied to the motors.
Charge the batt
ery.
A new batter
y should
have been charged for at least 12 hours
before using the vehicle for the first time.
After first-time use, recharge the battery
for at least 12 hours after each use. Never
charge the battery longer than 30 hours.
Check all wires and connectors. Make sure
the battery
connectors are tightly plugged
into the and that the
charger is plugged into the wall.
Make sure that there is power flow to the
wall outlet.
Do not
charge the battery longer tha
n 30
hours. If you suspect that
your battery
is damaged as a result of overcharging,
change with new original 6 Volt (4.0
Amp/Hr.) battery with built-in thermal fuse.
Do not use non-original substitute parts.
Even with proper care, a rechargeable
battery does not last forever. Average battery
life is 1 to 3 years depending on vehicle use
and use conditions. Replace only with an
original 6 Volt (4.0 Amp/Hr.) battery wi
th
built-in thermal fuse. Do not use non-original
substitute parts.
The built-in thermal fuse may “trip” and shut
down operation of the vehicle if the vehicle is
overloaded or the driving conditions are too
severe. Once a fuse has “tripped”, SET THE
To avoid repeated automatic shutdowns, do
not overload the vehicle by exceeding the
55 Ibs maximum weight capacity or by
towing anything behind the vehicle. Do not
drive up hills or run into fixed objects, whi
ch
can cause the wheels to stop spinning while
power is still being supplied to the motors.
battery terminals,

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dynacraft ultimate spider-man and is the answer not in the manual?

Dynacraft ultimate spider-man Specifications

General IconGeneral
BrandDynacraft
Modelultimate spider-man
CategoryGolf Cars
LanguageEnglish