DynaGen Tough Series - User Manual

DynaGen Tough Series
66 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Manual Revision: 7.0.0
Min. FW Revision: 1.88.01
Date Released: 2019-09-25
© 2019 DynaGen Technologies Inc
TG350 User Manual
Question and Answer IconNeed help?

Do you have a question about the DynaGen Tough Series and is the answer not in the manual?

Summary

Installation

General Wiring Notes

Provides essential guidelines for connecting wires to the controller for safe and effective operation.

Terminal Descriptions

Lists and describes the function of each terminal on the main and expansion connectors.

Wiring Harnesses

Details the different wiring harnesses and their terminal connections for various components.

Typical Wiring Diagram

Illustrates a typical wiring setup for the TG350 controller and its components.

Typical Wiring Diagram with RelayPak

Shows a typical wiring diagram specifically for the TG350 controller when used with a RelayPak.

Emergency Stop Wiring

Details the wiring required for implementing an emergency stop function for immediate shutdown.

CAN Bus Wiring

Provides guidelines for connecting the controller to a CAN bus engine for communication.

RelayPak (Optional)

Describes the optional RelayPak, its specifications, and usage for expanding I/O capabilities.

Using the Controller

Modes, Starting and Stopping

Details the different operational states and methods for starting the engine.

Starting Methods

Outlines the various ways the engine can be started using the controller.

Using Cooldown Mode

Details the cooldown mode functionality, including how it affects engine operation and start commands.

Failures

Describes conditions that cause the controller to shut down the engine to prevent damage.

Settings

Switched Inputs

Configures five switched inputs to perform specific functions when activated.

Sensors

Provides an overview of sensor inputs and their configurations for engine monitoring.

Timers

Configures the controller's internal clock and timing functions for various operations.

AC Monitor

Provides settings for configuring the controller's AC monitoring capabilities.

Communications

Details the controller's communication capabilities with other systems.

Other Config

Contains miscellaneous settings not covered in other sections.

Troubleshooting

Engine starts but the crank output does not turn off

Provides solutions for issues where the engine crank output fails to disengage after starting.

Controller displays Failure To Stop on a shutdown.

Explains how to resolve the "Failure To Stop" message by adjusting Energize to Stop settings.

DynaGen Tough Series Specifications

General IconGeneral
Number of Digital Inputs8
Number of Analog Inputs4
Storage Temperature-40°C to +85°C (-40°F to +185°F)
Communication PortsRS-485, Ethernet
ProtocolsModbus RTU, Modbus TCP/IP
EnclosureIP65
Input Voltage24V DC
Output Voltage24V DC