EasyManuals Logo

Dynamic RHINO2 DS160 User Manual

Dynamic RHINO2 DS160
163 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #113 background imageLoading...
Page #113 background image
6.5.8 System Options
6.5.8.1 Service Scheduler
Parameter Possible Values Default HHP Lite Std Adv
Service Scheduler No / Yes No
Service Period 0 - 5100h 5000h
The Service Scheduler is a preventative maintenance feature that allows the OEM to set up
scheduled servicing plans for their scooter customers.
To enable the Service Scheduler function, set Service Scheduler to 'Yes'.
Service Period sets the drive time between service schedules. When this number of hours
has been exceeded, the status indicator will flash slowly 3 times every time the scooter is
turned on or wakes up from sleep, to indicate that a service is due. This alarm is repeated
every 15 minutes. Setting the value of Service Period to zero will disable the Service
Scheduler and its alarm.
To clear the service indication, erase the controller history with the Wizard:
Tools->Erase Controller History.
Note
Erasing the controller history erases the fault log as well. Consequently, erasing the controller history to erase
the fault log will reset the service scheduler as well.
6.5.8.2 Actuator Time-Out
Parameter Possible Values Default HHP Lite Std Adv
Actuator Time-Out NOTUSED
6.5.8.3 Enable 1Hz Data
Parameter Possible Values Default HHP Lite Std Adv
Enable 1Hz Data No / Yes No
The RHINO2 controller transmits scooter status information from two single-wire
communication pins, TH14 and BC4 see 7.7.2 Physical interface. There are two packets
available:
l
Full Data packet
l
1 Hz Data packet
The Full Data packet is transmitted always; the 1 Hz Data packet is optional and only
transmitted if enabled with this parameter. The 1 Hz Data packet is limited to the following
status information:
l
Battery voltage
l
Ambient temperature
l
Motor current
GBK51948 RHINO2
Installation Manual Issue 5
Programming - Page 111

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dynamic RHINO2 DS160 and is the answer not in the manual?

Dynamic RHINO2 DS160 Specifications

General IconGeneral
BrandDynamic
ModelRHINO2 DS160
CategoryController
LanguageEnglish

Related product manuals