Loading...
Installation, Operation and Service Manual LKAT
2
+24V
© 2018 DynAmp, LLC Page 11
046404 E
Table 3.1
LKAT
2
System Specifications ( subject to change without notice ), continued
PHYSICAL
Measuring Head Weight
Typically 1 to 6 kg (3 to 13lbs.)
Metering Unit Weight ( Typical )
Typically 3kg (7lbs.)
Standard Length Head Connection Cables (2)
Optional custom lengths may be available up to 50m
(164 ft.)
10m (33 ft.)
Cable fixed to Measuring Head with connector for
Meter Unit on opposite end
Standard Length Signal Output Cable (1)
Optional custom lengths are available
30m (100 ft.)
Connector for Metering Unit on one end,
unterminated on opposite end
Standard Length Power Input Cable (1)
Custom lengths are available
10m (33 ft.)
Connector for Meter Unit on one end,
unterminated on opposite end
Figure 3.1
LKAT
2
Frequency Response
Normalized LKAT Bandwidth
Normalized Frequency f/fc ; fc = 1 1 2 .4 x 10
6
( A / s ) / I F S ( A )
F.S. Bus Current (kA)
5 to 50
60
70
80
90
100
Corner Frequency (kHz)
2.248
1.873
1.606
1.405
1.249
1.124
-40
-20
0
0.01 0.1 1 10 100
NORMALIZED BUS CURRENT
20 Log(I / IFS) ; (dB)