2. When the battery works with GOODWE, Solis, LUX, Sofar, DEYE(Sunsynk),
VICTRON, IMEON, Sungrow, SMA, RENAC, DELIOS, SAJ(CAN Comm) before
starting the battery, you need to put LV-Link DIP switch "# 3" to the "ON" position
(to the top), then turn on the batteries.
3. If the battery communicates with the Axpert-king/VMIII/MAX, Infinisolar,
Growatt SPH/SPA(CAN comm) GMDE, turn the LV-Link DIP switch "#2" to "ON"
position.
4. If the battery communicates with the Growatt SPF HVM-P/ES/WPV by RS485
communication, turn the LV-Link DIP switch "#2" and "#3" to "ON".
5. If the battery communicates with the Schneider Conext Series, turn the LV-Link
DIP switch "#1" and "#3" to "ON".
6. When you setup the LV-Link DIP as setting 1~4, all the PowerBox Pro or
PowerDepot H5B keep the DIP 0010,no need to change.
Note: For more information of matching inverter brands, please subject to the latest
document
<The list of compatibility between Dyness ESS and Inverters >.