8 EATON EP Control for Heavy Duty Series 2 Piston Pumps Parts & Service 08-10-0002-EN-0901 September 2001
Step 7
Using a 1/4" hex key (or 1/2"
socket/end wrench), remove the
five 5/16"-18 hex head cap screws.
Step 8
Carefully lift the valve assembly
straight up away from the pump.
Take care not to damage the feed-
back link or swashplate link.
Step 9
Caution must be used so that
the swashplate link remains
seated on the swashplate pin.