9SX UPS
9SX EBM
Installation
and user manual
Copyright © 2018 EATON
All rights reserved.
614-20306-00_EN
9SX 0-6 KVA EMEA

Questions and Answers:

Eaton 9SX2000I Specifications

General IconGeneral
Power Rating2000 VA / 1800 W
Output Frequency50/60 Hz
Form FactorTower
Frequency Range40-70 Hz
Operating Temperature0 to 40 °C
Storage Temperature-15 to 45 °C
Humidity0-95% non-condensing
Warranty2 years
Output Voltage220/230/240 V
Battery TypeSealed Lead Acid
Runtime at Half Load10 minutes
EfficiencyUp to 95%
Output ReceptaclesIEC C13
CommunicationUSB, RS-232
Input Voltage Range160 - 300 V
TopologyDouble Conversion Online
Typical Recharge Time4 hours to 90% capacity

Summary

Safety Instructions

Safety Precautions

Safety of Persons

Guidelines for safe handling and servicing of UPS systems and batteries.

Product Safety

Essential safety precautions for installing and operating the UPS equipment.

Additional Safety Measures

Special Precautions

Important safety measures for handling, installation, and maintenance of the UPS.

Installation Guides

EBM Tower Installation

UPS Tower Installation

UPS Rack Installation

EBM Rack Installation

Interfaces and Communication

Control Panel Overview

Description of the UPS graphical LCD control panel and its indicators.

UPS LCD Display

Display and User Settings

Communication Ports

Communication Ports and Cards

Information on RS232, USB ports, and installation of optional communication cards.

Remote Control Functions

Remote Control and Input Signals

Configuration and use of remote control functions and programmable signal inputs.

UPS Operation

Start-up and Normal Operation

Steps for starting the UPS, normal operation, and initiating battery power.

Starting the UPS on Battery Power

Procedure for initiating UPS operation using battery power.

UPS Operating Modes

UPS Shutdown Procedure

Instructions for safely shutting down the UPS system.

Bypass and Efficiency Settings

Battery Configuration

Battery Settings and Logs

Event and Fault Logs

Battery Replacement

Battery Replacement Guidance

Information on UPS battery lifespan and when replacement is recommended.

Replacing Internal Batteries

Replacing Internal Batteries

Detailed steps for replacing internal batteries in tower and rack UPS models.

Troubleshooting

Typical Alarms and Faults Resolution

Chart to diagnose and resolve common UPS alarms and faults.

Alarm Resolution and Support

Specifications

Related product manuals