EasyManua.ls Logo

Eaton EASY512-DC-RCX

Eaton EASY512-DC-RCX
12 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Electric current! Danger to life!
Only skilled or instructed persons may
carry out the following operations.
Lebensgefahr durch elektrischen Strom!
Nur Elektrofachkräfte und elektrotechnisch
unterwiesene Personen dürfen die im Folgenden
beschriebenen Arbeiten ausführen.
Tension électrique dangereuse !
Seules les personnes qualifiées et averties doivent
exécuter les travaux ci-après.
¡Corriente eléctrica! ¡Peligro de muerte!
El trabajo a continuación descrito debe ser realizado
por personas cualificadas y advertidas.
Tensione elettrica: Pericolo di morte!
Solo persone abilitate e qualificate possono eseguire
le operazioni di seguito riportate.
Электрический ток! Опасно для жизни!
Только специалисты или проинструктированные лица
могут выполнять следующие операции.
en
de
fr
es
it
ru
Emergency On Call Service: Local representative (Eaton.eu/aftersales) or +49 (0) 180 5 223822 (de, en) 1/12
02/18 IL05013015Z
Instruction Leaflet
Montageanweisung
Notice d’installation
Instrucciones de montaje
Istruzioni per il montaggio
Инструкция по монтажу
Relay
EASY512-…-…
EASY719-…-RC…
EASY721-…-TC…
EASY618-…-RE
EASY620-DC-TE
EASY200-EASY
EASY202-RE
EASY410-DC-…
ESC
O
K
D
E
L
A
LT
MN05013003Z…
(AWB2528-1508…)
www.eaton.eu/easy
ESC
OK
DEL
ALT
Question and Answer IconNeed help?

Do you have a question about the Eaton EASY512-DC-RCX and is the answer not in the manual?

Eaton EASY512-DC-RCX Specifications

General IconGeneral
ModelEASY512-DC-RCX
Power Supply Voltage24 V DC
Digital Inputs8
Relay Outputs4
Output Current8 A
Communication InterfaceRS-485
Mounting TypeDIN Rail
ClockYes
Protection ClassIP20
Contact ConfigurationSPDT
TypeRelay
Operating Temperature-25 to +55 °C

Summary

easyRelay Safety and Overview

Electrical Safety Warning

Highlights the danger to life from electric current and requires skilled personnel.

EASY5 Series: AC Standard Connection and Inputs

EASY5 AC Series: Standard Connection and Inputs

Details standard wiring and input specifications for EASY5 AC models.

EASY7 Series: AC Standard Connection and Inputs

EASY7 AC Series: Standard Connection and Inputs

Provides wiring diagrams and input parameters for EASY7 AC models.

EASY6 Series: AC Standard Connection and Inputs

EASY6 AC Series: Standard Connection and Inputs

Shows standard connection and input configurations for EASY6 AC models.

Relay Output Connections

Transistor Output Connections

Expansion Module Installation

Interface and Memory Card Usage

Mounting Positions and Certification

Hazardous Location Certification (CSA)

Information about suitability for hazardous locations as per CSA.