Warning that electric current poses a danger to life; only skilled persons may carry out operations.
Details transient surge suppression requirements for CSA and UL compliance, including voltage ratings and impulse withstand voltage.
Specifies conductor sizes (mm², AWG) and torque values (Nm, Ib-in) for electrical connections.
Crucial safety instruction to connect the device only when it is in a voltage-free state.
Illustrations showing the physical mounting of the device, including dimensions and connections.
Details how to connect a potentiometer and set the range and time parameters.
Provides examples of setting the range and time parameters for device operation.
Diagrams illustrating operation with two timed contacts linked via A2/X1, including ON-OFF functions.
Wiring diagrams for two timed contacts linked via A2/X1, showing terminal connections.
Diagrams for one non-delayed and one timed contact, unlinked via A2/X1, covering ON-OFF functions.
Wiring diagrams for one non-delayed and one timed contact, unlinked via A2/X1, showing terminal connections.
Descriptions of various function types like on-delayed, off-delayed, flashing, and pulse shaping.
Warning that electric current poses a danger to life; only skilled persons may carry out operations.
Details transient surge suppression requirements for CSA and UL compliance, including voltage ratings and impulse withstand voltage.
Specifies conductor sizes (mm², AWG) and torque values (Nm, Ib-in) for electrical connections.
Crucial safety instruction to connect the device only when it is in a voltage-free state.
Illustrations showing the physical mounting of the device, including dimensions and connections.
Details how to connect a potentiometer and set the range and time parameters.
Provides examples of setting the range and time parameters for device operation.
Diagrams illustrating operation with two timed contacts linked via A2/X1, including ON-OFF functions.
Wiring diagrams for two timed contacts linked via A2/X1, showing terminal connections.
Diagrams for one non-delayed and one timed contact, unlinked via A2/X1, covering ON-OFF functions.
Wiring diagrams for one non-delayed and one timed contact, unlinked via A2/X1, showing terminal connections.
Descriptions of various function types like on-delayed, off-delayed, flashing, and pulse shaping.
| Control Voltage | 24-240 V AC/DC |
|---|---|
| Mounting | DIN rail |
| Rated current | 8 A |
| Standards | IEC/EN 61812-1 |
| Protection class | IP20 |
| Time Range | 0.05 s - 300 h |
| Output | 2 CO |
| Type | Electronic timer relay |
| Setting range | 0.05 s - 300 h |
| Ambient temperature | -20 °C to +60 °C |