6
Reassembly
Refit the lid of the case, ensuring that the aerial cord is rmly gripped in the guides provided
and the sealing O” ring is correctly seated.
Replace the cross-headed screws into the holes and firmly screw the case together. It is
essential that the screws are tightly secured as the water resistance is dependent on this. If
necessary, re-seal the aerial entry/exit point, with DOW-CORNING sealant REF:RTV 3145.
ON NO ACCOUNT USE AN ACETIC ACID BASED SEALANT.
(Acetic acid sealants have a vinegar-like smell.)
Testing
Determine the limits of the transmitter’s range and inform the user of these limits. Check that
the unit will function in all areas where the user EXPECTS it to function and point out any
discrepancies.