What to do if Eaton Vickers CG-03 Control Unit has low or no pressure?
- BBrenda ChurchAug 11, 2025
If your Eaton Control Unit exhibits low or no pressure, several factors could be responsible. First, the valve may be improperly adjusted; in this case, adjust the valve to the proper setting. Another potential cause is an open vent connection, which can be resolved by plugging the vent connection. A plugged balance hole in the piston can also lead to this issue; remove the piston and clean it out. Finally, the poppet in the cover might not be seating correctly. If necessary, drain the system and refill it with clean fluid. Try backing off the adjusting screw several turns while running the pump to ensure no foreign matter is caught on the seat. If the problem persists, inspect the condition of the seat, spring, and poppet.