I-3618-SRevised 11/1/86
Directional Controls
Overhaul Manual
Vickers
®
Directional Controls

Questions and Answers

  • J
    Jeffrey ThomasAug 10, 2025
    What to do if my Eaton Vickers DF3S4-16 Control Unit valve spool fails to move?
    • E
      Emily LewisAug 10, 2025
      If the valve spool on your Eaton Control Unit fails to move, there are several potential causes. First, check for dirt in the system, and if present, disassemble, clean, and flush the unit. Next, verify the solenoids are working by checking the electrical source and the solenoids themselves. Also, ensure the unit is assembled correctly by referring to the appropriate figure and assembly procedure. Finally, confirm that the installation connections are correct by checking the installation drawings.
  • M
    Melissa BakerAug 25, 2025
    Why does my Eaton Vickers DF3S4-16 Control Unit valve produce an undesirable response?
    • K
      Kendra White MDAug 26, 2025
      An undesirable response from your Eaton Control Unit valve can stem from a few issues. Begin by checking the parts and installation drawings to ensure proper assembly and installation connections. Another potential cause is reversed solenoid wiring; try reversing the connections to the solenoids.

Eaton Vickers DF3S4-16 Series Specifications

General IconGeneral
SeriesDF3S4-16
TypeDirectional Control Valve
Mounting PatternCETOP 3
Maximum Operating Pressure350 bar
Fluid TypeMineral oil-based hydraulic fluids
Fluid Temperature Range-20°C to +80°C
Solenoid Voltage12 VDC, 24 VDC, 110 VAC, 220 VAC
Solenoid Connector TypeDIN 43650
ActuationSolenoid