MA-csau-01/01-1xIE.qxd/01.2015c /
136211178
Eaton Industries (Austria) GmbH, A-3943 Schrems
www.eaton.eu/documentation
EU
xComfort CSAU-01/01-10, CSAU-01/01-10I, CSAU-01/01-10IE
1
RLC
M
10 mm
1,5 mm²
CSAU-01/01 - 10 I E
EMS 3-2300 W
IN 230VAC
SA 230VAC/10A
SA: Switching Actuator / Vekslingsaktuator / Schakelactuator / Schaltaktor / Přepínací ovládací prvek /
Prepínací ovládací prvok / Odbiornik załączający / Actionneur de commutation / Kopplingsställdon / Attuatore di
commutazione / Actuator de comutare / Перемикаючий / пристрій / Indítószerkezet kapcsolás / Kytkinlaite
IN: Local Input / Lokal inngang / Lokale Ingang / Lokaler Eingang / Místní vstup / Miestny vstup, /
Wejście lokalne / Entrée locale / Lokal ingång / Input locale / Intrare locală / Локальний ввід /
Helyi bemenet / Paikallinen input
EMS: Energy Measurement Sensor / Energimålingssensor Sensor Meting / Energiemess-Sensor /
Senzor měření energie / Senzor merania energie / Czujnik pomiaru energii / Capteur de mesure de l’énergie /
Sensor för energimätning / Sensore di misurazione energia / Senzor de măsurare a energiei /
Датчик вимірювання енергії / Energia mennyiséget mérő érzékelő / Virran mittaussensori
(EN) Status: Extended Status Messaging (Routable)
(NO) Utvidet statutsmeldingshåndtering (Som kan rutes)
(NL) Uitgebreide Statusberichtgeving (Routable)
(DE) Erweiterte Statusmeldungen (Routbar)
(CZ) Rozšířený stav hlášení (směrovatelný)
(SK) Rozšírený stav hlásenia (smerovateľný)
(PL) Rozszerzony zasięg komunikatów (rutowany)
(FR) Messagerie d’état étendue (routable)
(S) Utökade Statusmeddelanden (Routbar)
(IT) Messaggistica status estesa (instradabile)
(RO) Stare prelungită de schimb de mesaje (Rutabil)
(UK) Подача повідомлень розширеного стану (Маршрутизована)
(HU) Kiterjesztett Állapotüzenet küldés (Irányítható)
(FI) Laajennettu tilan viestintä (Reititettävä)
-5°C - +55°C
-25°C - +70°C
See derating
868,3 MHz
IP20
RM Version V41a
SHC-RF Version 2.00
ECI-RF Version 2.00
USB-RF Version 2.00
MRF
Min. Version 2.34

Other manuals for Eaton xComfort CTAA-01/04

Question and Answer IconNeed help?

Do you have a question about the Eaton xComfort CTAA-01/04 and is the answer not in the manual?

Eaton xComfort CTAA-01/04 Specifications

General IconGeneral
Product nameEaton xComfort CTAA-01/04
CategoryController
Power Supply230 V AC
Protection ClassIP20
Input Voltage230 V AC
Frequency50/60 Hz
Communication ProtocolxComfort
Operating Temperature0°C to 50°C
Relative Humidity5% to 85% non-condensing
MountingDIN rail

Summary

Product Overview and Safety

Safety and Electrical Precautions

Highlights critical safety warnings and installation by qualified electricians.

Product Functions

Describes switching actuator, local input, and energy measurement sensor functions.

Wiring and Performance Characteristics

Wiring Examples

Illustrates wiring for pushbuttons/switches and hotel setups.

Wireless Range and Interference

Specifies operating range and signal interference factors.

Installation Steps for CSAU Series

CSAU-01/01-10I(E) Installation

Step-by-step visual guide for installing the CSAU-01/01-10I(E) model.

CSAU-01/01-10 Installation

Step-by-step visual guide for installing the CSAU-01/01-10 model.

Declaration of Conformity

Product Compliance Statement

Declares conformity of Eaton switching actuators to EU directives and standards.

CTAA Series Overview and Compatibility

CTAA Installation Examples

Visual examples for installing CTAA series devices.

CTAA Series Installation Procedures

Connecting Actuators and Sensors

Illustrates connecting actuators to sensors and installing modules.

CTAA Series Installation Details

General Product Usage and Installation

Installation Requirements and Safety

Details installation by specialists, fuse protection, and stress restrictions.

Product Applications and Guarantees

Prohibited Applications

Lists applications where xComfort products MUST NOT be used, like safety functions.

Warranty and Liability

Defines warranty conditions, liability, and consequences of non-compliance.