EasyManua.ls Logo

Eaton SV9000 User Manual

Eaton SV9000
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
MN04001002E For more information visit:
www.eatonelectrical.com
SV9000 AF Drives — Motor Pump Enhanced Protection Application
Application Manual
June 2004
Supersedes February 2001

Other manuals for Eaton SV9000

Question and Answer IconNeed help?

Do you have a question about the Eaton SV9000 and is the answer not in the manual?

Eaton SV9000 Specifications

General IconGeneral
BrandEaton
ModelSV9000
CategoryController
LanguageEnglish

Summary

1 General

2 Control I/O

Defines terminal functions, input/output signals, and their descriptions.

3 Control Signal Logic

5 Basic Parameters, Group 1

5.1 Parameter Table

Lists and describes basic parameters with their ranges and defaults.

5.2 Description of Group 1 Parameters

1.5 Reference selection

Defines the source for the speed reference signal.

1.7 Current limit

1.8 V/Hz ratio selection

1.9 V/Hz optimization

Group 3, Output and supervision parameters

Group 4, Drive Control Parameters

Group 5, Prohibit frequency parameters

6.1 Motor control mode

Selects the primary motor control method (frequency, speed, torque).

Group 7, Protections

7.3 Phase supervision of the motor

7.4 Earth fault protection

7.5 Motor thermal protection

7.6 Motor thermal protection break point current

7.7 Motor thermal protection zero frequency current

7.8 Motor thermal protection time constant

7.9 Motor thermal protection break point frequency

7.10 Stall protection

7.11 Stall current limit

7.12 Stall time

7.13 Maximum stall frequency

7.14 Underload protection

7.15 Underload prot., field weakening area load

7.16 Underload protection zero frequency load

7.17 Underload time

7.18 Phase supervision of the supply voltage

7.19 Thermistor input of I/O-Expander

7.20 Response to fieldbus fault

Group 9, Torque Control

9.2 Torque reference scaling bias

9.3 Torque reference scaling gain

9.4 TC time constant

9.5 TC min. control limit

Group 10, Fieldbus Parameters

10.2 MODBUS Slave address

10.3 Baud rate

10.6 Profibus slave address

10.7 Profibus baud rate

Group 11, Digital Input Parameters

11.2 DIB4 function (terminal 14)

11.3 DIB5 function (terminal 15)

11.4 DIB6 function (terminal 16)

11.5 DIC1 function (Refer to page 16)

11.6 DIC2 function

11.7 Hot Motor Winding Delay

11.8 Hot Motor Bearing Delay

11.9 Seal Leak Detection Delay

11.10 High Vibration Delay

Group 12, Digital Output Parameters

12.2 Relay output function

12.3 Relay 2 output function

12.4 Relay 3 output function

12.5 Relay 4 output function

12.6 Relay 5 output function

Fault Code

50 Hot Motor Winding

51 Hot Motor Bearing

52 Seal Leak Detection

53 High Vibration

Monitoring Data

9 SV9IOC103 Control Connections

209 DIC1

210 DIC2

211 DIC3

212 DIC4

213 DIC5

215 Iout+

223 RO3/1

225 RO4/1

227 RO5/1

Related product manuals