30 Analog input/output module ±10 V XN-322-8AIO-U2
30.7 Memory layout
231 XN300 slice modules 02/24 MN050002EN Eaton.com
0x30B3 0x6401 0x6xx1
SUB 03
2 InputChannel3 0x0086
0x30B4 0x6401 0x6xx1
SUB 04
2 InputChannel4 0x0088
0x30B5
–
0x6xxA
SUB 01
2 WireBreakDiag Bit 0 1: Cable break input
AI1
0x008A
Bit 1 1: Cable break input
AI2
Bit 2 1: Cable break input
AI3
Bit 3 1: Cable break input
AI4
Bit 4 1: Reference Low
Voltage
Bit 5 1: Reference Overcur-
rent
Bit 6-15 reserved
0x4001 – 0x9xx0
SUB 08
max.10 CAN: Serial-
Number
EC: Serialnumber
–
0x4004 – 0x8xx1
SUB 01
1 UserLEDControl
–
0x400C – – Max.
25
ProductName
–
0x4080 – – 2 FirmwareVersion
–
0x50B0 0x8xx6
SUB 01
2 AnalogInputSe-
lection
Parameter defini-
tion channel
Measure
d value 1
(AI1)
Bit 0 (AI1) 0: Differential
measurement
1: AI1- grounded
measurement
0x0106
Measure
d value 2
(AI2)
Bit 1 (AI2) 0: Differential
measurement
1: AI2- grounded
measurement
Measure
d value 3
(AI3)
Bit 2 (AI3) 0: Differential
measurement
1: AI3- grounded
measurement
Measure
d value 4
(AI4)
Bit 3 (AI4) 0: Differential
measurement
1: AI4- grounded
measurement
– Bit 4-15 reserved
CAN
Object
Index
Default
CAN
Mapping
EtherCAT
Object
Index
Size
(byte)
Local I/O
description
Local I/O
addresses