EasyManua.ls Logo

Eberg ELIO E35T1 - R290 Refrigerant Gas Safety Information; Handling and Storage Precautions for R290

Eberg ELIO E35T1
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ELIOEN
31
www.eberg.eu
supervision of the person competent in the use of ammable refrigerants.
22. Do not operate or stop the unit by inserting or pulling out Die power plug, it may cause electric
shock or re due to heat generation.
23. Unplug the unit if strange sounds, smell, or smoke comes from it.
Notes:
- If any parts damage, please contact the dealer or a designated repair shop;
- In case of any damage, please turn o the air switch, disconnect the power supply, and contact the
dealer or a designated repair shop;
- In any case, the power cord shall be rmly grounded;
- To avoid the possibility of danger, if power cord is damaged, please turn o the air switch and disconnect
the power supply. It must be replaced from the dealer or a designated repair shop.
If the appliance have the Wi-Fi function , the transmission power: less than 20dBm, and the radio frequency
range is: 2412MHz-2472MHz.
Warning
Do not use means to accelerate the defrosting process or to clean, other than those recommended by
the manufacturer. The appliance shall be stored in a room without continuously operating ignition
sources (for example: open ames, an operating gas appliance or an operating electric heater. Do not
pierce or burn.
Be aware the refrigerants may not contain an odour. Appliance shall be installed, operated and stored
in a room with a oor area larger than X m2.
Quantity of R290 gas in charge (see rating label on
the appliance) (g)
Minimum size of the site for use and
storage (m²)
m<152
4
152m185
9
186m225
11
226m270
13
271m290
14
291m300
15
Specic information regarding appliances with R290 refrigerant gas.
This appliance contains Y g (see rating label back of unit) of R290 refrigerant gas.
R290 is a refrigerant gas that complies with the European directives on the environment.
Do not puncture any part of the refrigerant circuit.
If the appliance is installed, operated or stored in an unventilated area, the room must be designed
to prevent to the accumulation of refrigerant leaks resulting in a risk of re or explosion due to
ignition of the refrigerant caused by electric heaters, stoves, or other sources of ignition.
The appliance must be stored in such a way as to prevent mechanical failure.
Individuals who operate or work on the refrigerant circuit must have the appropriate certication
issued by an accredited organization that ensures competence in handling refrigerants according to
a specic evaluation recognized by associations in the industry.
Repairs must be performed based on the recommendation from the manufacturing company.
Maintenance and repairs that require the assistance of other qualied personnel must be performed
under the supervision of an individual specied in the use of ammable refrigerants. Ducts
connected to an appliance shall not contain a potential ignition source.