Operating instructions
M3G084-GF08-81
Translation of the original operating instructions
4.5 Connection diagram
Drawing preliminary!
No. Conn. Designation Color Function/assignment
1 1, 2 PE green/
yellow
Protective earth
1 3 N blue Power supply, neutral conductor, see nameplate for voltage range, 50/60 Hz
1 4 L black Power supply, phase, see nameplate for voltage range, 50/60 Hz
1 5 COM white 1 Floating status contact, break for failure (2 A, max. 250 VAC, min. 10 mA)
1 6 NC white 2 Floating status contact, break for failure
2 8 0 -10 V yellow Control input, set value 0-10 VDC, impedance 100 kOhm, SELV
2 10 P orange not used
2 11 10 VDC red Voltage output 10 VDC (±3%), max. 10 mA, power supply for external devices (e.g.
potentiometers), SELV
2 12 GND blue Reference ground for control interface, SELV