Chengdu Ebyte Electronic Technology Co., Ltd. E104-BT5040U Datasheet
Copyright©2020, Chengdu Ebyte Electronic Technology Co., Ltd.
2. Parameters
2.1 Limit Parameters
The main parameters
Value
Notice
Min
Max
USB power supply voltage (V)
0
5.5
Over 5.5V will permanently burn the module
VBUS power supply hole (V)
0
5.5
Over 5.5V will permanently burn the module
VDD power supply hole power
supply (V)
0
3.6
Over 3.6V will permanently burn the module
Blocking power (dBm)
-
10
It is less likely to burn when used at close range
Working temperature ()
-40
+85
Industrial grade
2.2 Working Parameters
Description
Value
Min
Typical
Max
Working voltage (V)
4.35
5
5.5
Communication level (V)
0
3.3
3.6
Working temperature ()
-40
-
+85
Working frequency (MHz)
2360
2402
2500
TX
TX only run current (DCDC, 3V) PRF =+8 dBmmA
17.05
TX only run current (DCDC, 3V) PRF =+4 dBm
mA
12.68
TX only run current (DCDC, 5V, REG0 out = 3.3 V)PRF
= 0dBm
mA
7.25
TX only run current (DCDC, 3V)PRF = 0dBm
mA
7.63
TX current (3V) 1Mbps BLE measured from VBAT with
PRF=9dBmmA
32
RX
RX only run current (DCDC, 3V) 1Mbps / 1Mbps BLE
mA
7.71
RX only run current (DCDC, 3V) 2Mbps / 2Mbps BLE
mA
8.27
Max TX Power
dBm
7.5
8
8.5
Rx Sensitivity
dBm
-103dBm@BLE 125kbps
-95dBm@BLE 1Mbps