22
description
example
AT+CDEVEUI=AABBCCDD00112233
OK
Precautions
Set or read DevEUI, return Y1Y2 ... Y8, hexadecimal format, value 8 bytes.
command
character
command
type
command format
response
CAPPEUI
( Set AppEUI )
test
command
AT+CAPPEUI=?
+CAPPEUI=<AppEUI:length is 16>
query
command
AT+CAPPEUI?
+CAPPEUI:<value>
OK
set
command
AT+CAPPEUI=<value>
OK
Parameter
Description
<value>: Node AppEUI
Return
value
description
example
AT+CAPPEUI=AABBCCDD00112233
OK
Precautions
Used when OTAA, set or read AppEUI, return Y1Y2 ... Y8, hexadecimal format,
value 8 bytes.
command
character
command
type
command format
response
CAPPKEY
( Set AppKey )
test
command
AT+CAPPKEY=?
+CAPPKEY=<AppKey:length is 32>
query
command
AT+CAPPKEY?
+ CAPPKEY:<value>
OK
set
command
AT+CAPPKEY=<value>
OK
Parameter
Description
<value>: Node AppEUI
Return
value
description
example
AT+CAPPKEY=AABBCCDD00112233AABBCCDD00112233
OK
Precautions
Used in OTAA, set or read AppKey, return Y1Y2 ... Y16, hexadecimal format, value
16 bytes.
command
character
command
type
command format
response
CDEV ADDR
( set DevAddr )
test
command
AT+CDEVADDR=?
+CDEVADDR=<DevAddr:length is 8
Device
address of ABP mode>

Related product manuals