30
00 11 22 33 44 55 66 77 88 99
A1 A1 01 0A
A1 A1 04 02 00 00
1. The module must be connected to the network before sending data,
otherwise the data cannot be sent and the return value of A1 A1 00 will be received.
2. When the module is waiting for the server to respond, it cannot exit the
transparent transmission mode. It needs to wait for the server to respond or send
overtime before sending +++ (hex: 2B 2B 2B) to exit the transparent transmission
mode.
3. Before entering the transparent transmission mode, please set
AT+CMR=0,10 (use aperiodic reporting), AT+CLINKCHECK=0 (disable network
verification).
CCONFIRM
( Set Uplink
Transmission
Type )
+DRX:<Length>,<Payload>
OK
<value>: as follows.
0: UnConfirmed up message
1: Confirmed up message
Need to set before sending data
CAPPPORT
( Set uplink
data port
number )
<value>: as follows:
The port used, the data format is decimal, the factory value is 10.
Value range: 1~223;
Note: Port: 0x00 is the MAC command of LoRaWAN
Need to set before sending data