EasyManua.ls Logo

Ebyte E840-DTU - Page 29

Ebyte E840-DTU
33 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chengdu Ebyte Electronic Technology Co.,Ltd E840-DTU(4G-02E) User Manual
Copyright ©2012–2019
,
Chengdu Ebyte Electronic Technology Co.,Ltd
29
AT+ SMSINFO
Function
:
configure/inquire SMS configuration identifier ID
Format
:
transmit
transmit:AT+ SMSINFO =<Info> <CR>
return
:
<CR><LF>+OK<CR><LF>
Inquire
transmit
:
AT+ SMSINFO <CR>
return:<CR><LF>+OK=<info> <CR>
Parameter
:
Info :remote SMS configuration identifier ID
AT+MODBUS
Function: configure/ inquire if Modbus RTU/TCP switch function is enabled
Format
:
configure
transmit:AT+ MODBUS =<state> <CR>
return
:
<CR><LF>+OK<CR><LF>
inquire
transmit
:
AT+ MODBUS <CR>
return:<CR><LF>+OK=<state> <CR><LF>
Parameter: state
ON Modbus RTU/TCP switch is on
OFF Modbus RTU/TCP switch is off
AT+MTCPID
Function
:
configure/ inquire Modbus RTU/TCP event identifier
Format
:
configure
transmit
:
AT+ MTCPID =<id> <CR>
return:<CR><LF>+OK<CR><LF>
inquire
transmit:AT+ MTCPID <CR>
return
:
<CR><LF>+OK=<id> <CR><LF>
Parameter: id (0~65535 )2 bytes
Remark
:
when ID is 0
,
any modbusTCP received will switch to corresponding RTU protocol
,
otherwise, only
when id is matched can it switch
AT+NETHEAD
Function: Set / query network AT command header
Format: Configuration
Send: AT+ NETHEAD =<value> <CR>
Returns: <CR><LF>+OK<CR><LF>
Inquire
Send: AT+ NETHEAD <CR>
Returns: <CR><LF>+OK=<value><CR><LF>
Parameters: value, set / query network AT command header
Remarks: The network AT identifier can be up to 19 characters long.
AT+MQTTMODE
Function: Set / query MQTT mode
Format: Configuration
Send: AT+ MQTTMODE =<mode> <CR>
Returns: <CR><LF>+OK<CR><LF>
Inquire
Send: AT+ NETHEAD <CR>
Returns: <CR><LF>+OK=<value><CR><LF>