33
33
ERROR
CODES
ERROR
CODES
CAUSES POSSIBLE
CAUSES
CORRECTIVE
MEASURES
ADDITIONAL
INFO
08H GF
Inverter is grounded
abnormally.
Inverter is ground
abnormally.
Replace inverter.
Inverter is grounded
abnormally.
Broken gasket on the
bottom of AC motor
caused metal cover of
motor to product arc
flash to the frame of
treadmill.
Replace motor gasket.
09H OH
The inverter is
overheated.
Fan on inverter is dusty. Clean fan on inverter.
Running belt/deck is
aging.
Add lubricant to
running belt.
Running belt/deck is
broken.
Replace running belt
and deck.
Inverter is broken. Replace inverter.
0AH OL
Motor overload
abnormal.
Running belt/deck is
aging.
Add lubricant to
running belt.
Running belt/deck is
broken.
Replace running belt
and deck.
Inverter is broken. Replace inverter.
Motor is broken. Replace motor.