35
35
ERROR
CODES
ERROR
CODES
CAUSES POSSIBLE
CAUSES
CORRECTIVE
MEASURES
ADDITIONAL
INFO
23H LE
The inverter displays
low voltage warning.
Voltage of utility power
is too low.
Check if utility power
supply matches
voltage of inverter.
Inspect whether
the utility power
is 110/220V.
Inverter is broken. Replace inverter.
Filter is broken. Replace filter.
Choke is broken. Replace choke.
25H ESP
The inverter displays
emergency stop.
Check if
safety key wire
is disconnected.
Check wires.
Safety key
switch is broken.
Replace safety key
switch.
Control wire
is broken.
Replace control wire.
Inverter is broken. Replace inverter.
PCB in console
is broken.
Replace PCB in con-
sole.
42H HT
The inverter displays
high temperature.
Running belt/deck is
aging.
Add lubricant to
running belt.
Running belt/deck is
broken.
Replace running belt
and deck.
Inverter is broken. Replace inverter.