ASSEMBLY PB-255LN
18 X7501186403
© 07/22 ECHO Incorporated
4. After inserting main blower pipe
into fan case so that line (F)
meets locking ring (C), rotate
locking ring clockwise 1/8 turn to
lock main blower pipe in place.
5. Align groove (H) in fan-head pipe
with tabs (G), and slide fan-head
pipe over main pipe until there is
light resistance. Do not force
connection.
6. Hold main pipe, and turn fan-
head pipe clockwise, engaging
positive locking channels until
connection is firm.
Note: Blower use will eventually loosen pipe connections. Exclusive
positive locking system allows pipes to be tightened. If
loosening occurs, remove fan-head pipe, and install
according to instructions 5 & 6.
Remove Blower Pipes
1. Release locking ring (C) with a
coin or screwdriver (B), and
rotate ring so that lock symbol is
at top of ring.
F
C
Blower Pipe
Blower Pipe
(main)
G
H
coin