Bedienungsanleitung / User manual COMPACT HX-2
ENGLISH
22
Follow the steps as indicated below:
1.
Brew group at the beginning
2.
Remove the countersunk screw in the
middle of the brewing unit
3.
Remove the shower screen and the
shower plate
4.
Remove the thin gasket of the shower
tray
5.
Now the group gasket can be
removed.
6.
Remove the group gasket with a
screwdriver
7.
Clean the groove before inserting the
new group gasket
8.
Insert the new group gasket with the
rounded side facing upwards
9.
Replace the gasket of the shower tray
(see point 4) and the shower plate
The steam nozzle is blocked
Clean the holes of the steam nozzle carefully with a needle or with a paper clip.
For this purpose, the steam nozzle may be unscrewed as well.
Important
Do not lose the small gasket between the steam nozzle and the thread! Item no. B7496083.
Afterwards replace the steam nozzle.

Table of Contents