ESI(Ultra) Service Manual
09.2018
1/62
www.ecoer.com
Manufacturer reserves the right to change specifications or designs without notice.
ESI(Ultra) Unitary System
Service Manual
Contents
1. General Information------------------------------------
2. ESI(Ultra) Unitary System---------------------------
2.1 Refrigerant Circuit----------------------------------
2.2 Function and Control------------------------------
2.3 Field Setting-----------------------------------------
3. Troubleshooting---------------------------------------
4. Appendix------------------------------------------------
4.1 Sensor Characteristics-------------------------------
4.2 Wiring Diagram-------------------------------------
2
3
3
7
17
25
57
57
61

Table of Contents

Other manuals for Ecoer EODA18H-2436

Questions and Answers

  • M
    Martin LiAug 13, 2025
    What to do if my Ecoer Heat Pump system cannot cool well?
    • R
      Russell TaylorAug 13, 2025
      If your Ecoer Heat Pump system isn't cooling well, several factors could be the cause. It could be due to high or low outside temperatures, which activate a normal protection control to limit RPS. Other potential causes include a dirty air filter or a blocked outlet of the indoor unit (in which case you should replace the air filter and remove any obstacles), too little refrigerant in the system (check the refrigerant amount or for any leaks), or a blocked refrigerant in the condenser coil (counterclockwise the TXV, ensuring the refrigerant coefficient is 0.6).
  • P
    Patricia PhillipsAug 16, 2025
    What to do if my Ecoer Heat Pump system cannot heat well?
    • C
      Christopher SmithAug 16, 2025
      If your Ecoer Heat Pump system isn't heating well, several factors could be the cause. If the outside temperature is too low and there's no third-party heat inside, install auxiliary heat for backup (dual-heating is recommended). Other potential causes include a dirty outdoor coil (clean the outdoor coil), a dirty air filter (replace the air filter), lack of refrigerant (check refrigerant amount or any leaks), or using micro channel coil in heating (no micro channel coils shall be used for heat pump).
  • H
    harringtonericAug 20, 2025
    Why does my Ecoer Heat Pump system not start-up but the digital tube shows normally?
    • S
      Stephanie HoffmanAug 20, 2025
      There are a couple of reasons why your Ecoer Heat Pump system might not be starting up even though the digital display appears normal. First, check that the Y/O/C wirings are correctly connected and that the cooling/heating setting temperature from the thermostat is properly set. Second, the thermostat might be incompatible; try using other traditional 24Vac thermostats.
  • G
    grayharryAug 23, 2025
    Why does my Ecoer Heat Pump system operate mode reversely?
    • D
      davidwhiteAug 23, 2025
      If your Ecoer Heat Pump system is operating in reverse mode, it is probably due to an incorrect O/B signal selection. Choose 'O' for cooling from the thermostat.
  • A
    Amy SmithAug 27, 2025
    What to do if my Ecoer EODA18H-2436 Heat Pump cannot cool well?
    • C
      Carol Cabrera MDAug 27, 2025
      If your Ecoer Heat Pump isn't cooling effectively, several factors could be the cause. The outside temperature might be too high, triggering normal protection controls. Alternatively, the outside temperature could be too low, so you should ensure the cooling loads. A dirty air filter or blocked duct can also restrict airflow; replace the air filter and clear any obstructions. Low refrigerant levels or a refrigerant blockage in the condenser coil could also be the reason. In the latter case, counterclockwise the TXV, ensuring the refrigerant coefficient is 0.6. Finally, check for refrigerant leaks and replenish if needed.
  • J
    Jared WilliamsAug 31, 2025
    Why is my Ecoer EODA18H-2436 not heating well?
    • J
      Jose HoffmanAug 31, 2025
      If your Ecoer Heat Pump is struggling to heat, it could be due to several reasons. If the outside temperature is too low and there's no third-party heat source, consider installing auxiliary heat for backup. A dirty outdoor coil or one covered in heavy snow can also reduce heating efficiency; clean the outdoor coil in this case. Also, replace the air filter if it is dirty. Ensure that micro channel coils have not been used for the heat pump, as they are incompatible. Finally, check for refrigerant leaks and replenish if necessary.
  • P
    paulclarkSep 4, 2025
    How to fix Ecoer EODA18H-2436 Heat Pump that does not start but shows normally?
    • C
      Clinton SmithSep 4, 2025
      If your Ecoer Heat Pump's digital display appears normal but the system won't start, there are a couple of potential causes. First, check that the Y/O/C wirings are correctly connected and that the cooling/heating setting temperature on your thermostat is properly set, ensuring there is 24 VAC for the Y signal from the thermostat. Second, your thermostat might be incompatible; try using another traditional 24VAC thermostat.
  • M
    Meghan WoodardSep 8, 2025
    What to do if Ecoer EODA18H-2436 operates mode reversely?
    • M
      Michael SimonSep 8, 2025
      If your Ecoer Heat Pump is operating in reverse mode, the issue is likely due to an incorrect O/B signal selection. To resolve this, choose 'O' for cooling at the thermostat.

Summary

ESI(Ultra) Service Manual

ESI(Ultra) Unitary System

Refrigerant Circuit Overview

Details functional parts layout and components of the refrigerant circuit.

Component Functions and Diagrams

Describes functions of major components and illustrates refrigerant flow.

Function and Control

Basic Control Logic

Details cooling, heating, and defrost control strategies and parameters.

Protection Controls

High Pressure Protection Control

Details high pressure protection thresholds and system response.

Low Pressure Protection Control

Details low pressure protection thresholds and system response.

Discharge Temperature Protection

Details discharge temperature protection thresholds and system response.

INV Module Temperature Protection

Details inverter module temperature protection thresholds and system response.

Compressor Over-Current Protection

Details compressor over-current protection thresholds and system response.

Field Setting

Troubleshooting

Outdoor Unit Error Codes

Display Error Code Troubleshooting

Pressure Protection and Sensor Faults

Troubleshooting high/low pressure protection and sensor faults.

Temperature Sensor Faults

Diagnosing and resolving faults related to various temperature sensors.

Compressor Protection and Faults

Troubleshooting compressor over-current, voltage, and module protection.