What to do if Ecoflam MAX GAS 350 PR ignition failure?
- AAmber FrancisAug 2, 2025
If the Ecoflam Burner experiences ignition failure, you should check and clean the ignition electrode(s) and connections.
What to do if Ecoflam MAX GAS 350 PR ignition failure?
If the Ecoflam Burner experiences ignition failure, you should check and clean the ignition electrode(s) and connections.
What to do if Ecoflam MAX GAS 350 PR starts but goes off?
If your Ecoflam Burner starts but then goes off, a possible cause is related to the gas pressure. Check the gas pressure to ensure it is at the correct level.
Why is there a gas pressure drop in my Ecoflam MAX GAS 350 PR Burner?
A gas pressure drop in your Ecoflam Burner could be due to blockages in the gas supply lines. Check the gas supply lines and ensure there are no obstructions.
What to do if there is insufficient air supply in Ecoflam Burner?
If there is insufficient air supply in your Ecoflam Burner, check the air flap position and connections to ensure they are correctly set.
How to fix a faulty safety switch on an Ecoflam Burner?
If you have a faulty safety switch on your Ecoflam Burner, replace the defective safety switch.
How to troubleshoot no burner control indicator light on Ecoflam?
To troubleshoot the absence of a burner control indicator light on your Ecoflam Burner, check the control and safety devices, such as the boiler thermostat, low water level detector, limit switch, etc., to ensure they are adjusted correctly.
Type | Gas Burner |
---|---|
Ignition | Electronic |
Air Pressure Switch | Yes |
Gas Pressure Switch | Yes |
Fuel | Natural Gas, LPG |
Stages | 2 |
Thermal Output | 350 kW |
Control System | Electronic |
Flame Supervision | Ionization |
Dimensions | Varies depending on model configuration. Consult manufacturer's documentation. |
Weight | Varies depending on model configuration. Consult manufacturer's documentation. |
The working field shows burner output as a function of combustion chamber pressure.
Explains pre-purge, monitoring, safety functions, and controller shutdown actions.
Details specific safety measures like flame detection and air/gas failure response.
Essential checks before initial burner commissioning.
Initial setup of servomotor positions before ignition.
Sequence for regulating burner output: max power, then low flame setting.
Procedures for adjusting minimum/maximum output and air flow for flame stability.
Procedure for calibrating the air pressure switch for optimal combustion.
Important safety instruction to disconnect electrical supply before maintenance.
List of maintenance tasks for burner components like gas supply, electrical connections, and filter.
Initial checks and table for diagnosing and repairing common burner malfunctions.
Accessing and navigating the fault diagnosis menu to view fault details.