POWER
DAMPER
1
24V
24C
Z1-PO
Z1-PC
Z3
ADJUST SETTINGS
RC
RH
COM
W2
O/B
Y1
Y2
G
EQUIPMENT
Z1
Z4
REMOVE TO SEPARATE
RC & RH TERMINALS
COM
ZONE
1
STAT
R
EC
Y
G
O/B
W
ZONE
2
STAT
R
C
Y
G
O/B
W
DAMPER
2
Z2-PO
Z2-PC
COM
DAMPER
3
Z3-PO
Z3-PC
COM
DAMPER
4
Z4-PO
Z4-PC
COM
Z2
ZONE
3
STAT
R
C
Y
G
O/B
W
C
ZONE
4
STAT or FA
R
C
Y
G
O/B
W
STAT
TYPE
RESET
W1
Y2
W2
G
Y1
SMART LINK
1
GND
2
SA SENSOR
SA1
SA2
W1
EH
I88
HI TEMP
LO TEMP
SUPPLY
PURGEDELAY ECO
HEAT PUMP
B
DUAL FUEL
ELECTRIC
GAS/ELECT
RVS. VLV. O
NORMAL
FAN GAS
LOCKOUT2
nd
STAGE
SMART LINK
ZONES (1 4)
ZONES (5 8)
FRESH AIR
ecojay
SmartZone
300
mA
24 VAC
TRANSFORMER
ecojay
COM
PC
PO
SUPPLY TEMP SENSOR
SAS
(INCLUDED)
4" Stainless
Temp Probe
w/ 10 ft wire &
EZ Plug
TEMPERATURE SENSOR (SAS) INCLUDED must be securely installed
and properly located for SmartZone to operate properly. --“ will be flashing
on the display if SAS not plugged into the SmartZone board.
Drag the side
handles to
change the
width of the
text block.
SELECT
ZONE
1
Press the STAT
TYPE Button...
2
HI TEMP
LO TEMP
SUPPLY
PURGEDELAY ECO
TWO TIMES...
3
HI TEMP
LO TEMP
SUPPLY
PURGEDELAY ECO
THREE TIMES...
4
HI TEMP
LO TEMP
SUPPLY
PURGEDELAY ECO
FOUR TIMES
I
HI TEMP
LO TEMP
SUPPLY
PURGEDELAY ECO
ONE TIME...
4 Zone ONLY
ADJUST
STAT TYPE
GE
HI TEMP
LO TEMP
SUPPLY
PURGEDELAY ECO
FA
HI TEMP
LO TEMP
SUPPLY
PURGEDELAY ECO
2
Press the UP and
DOWN Arrows
GAS / ELECTRIC
[Standard Heat/Cool Thermostat]
HP
HI TEMP
LO TEMP
SUPPLY
PURGEDELAY ECO
HEAT PUMP
Thermostat
FRESH AIR
(Available on Zone 4 ONLY)
THERMOSTAT TYPE SETUP
On Heat Pump equipment ONLY, either Gas/Electric or Heat Pump thermostats can
be used. The SmartZone controller MUST be set for the thermostat type being
used or the equipment will not operate properly with potential risk of damage.
Set the thermostat type as shown below using the “STAT TYPE” and “Arrow” buttons.
NOTE: When GAS/ELECTRIC Equipment, this option is NOT available, all thermostats
will be GAS/ELECTRIC.
NOTE 2: When using SmartLink for 8X system, secondary controller stat type must
also be set using the same method.
Y = Cool
W = Heat
DIP #2: Rvs. Vlv. O
(Default)
Y = Heat
Y + O = Cool
DIP #2: Rvs. Vlv. B
Y = Cool
Y + B = Heat
W = Em. Heat (Zone1
must initialize)
If FA is selected, Zone
4 Damper will operate
as a Fresh Air Damper.
SEE NEXT PAGE
FOR DETAILS
USE 18 GAUGE Solid Conductor Wire
NOTE: Disconnect power to equipment transformer while wiring SmartZone
Connect equipment according to manufacturers instructions.
EQUIPMENT WIRING
2-WIRE
SPRING OPEN
POWER CLOSE
3-WIRE
POWER CLOSE
POWER OPEN
REMOVE IF TWO EQUIPMENT
TRANSFORMERS ARE USED
(ONE FOR HEATING AND ONE
FOR COOLING) SEE PREVIOUS
PAGE FOR MORE DETAILS.
REPLACE FUSE WITH
300mA Fuse (5X20mm)
Spare Included
POWER WIRING
6 7
¼” Diameter
Hole Required
for mounting
GAS/ELECTRIC or HEAT PUMP w/ Dual Fuel
INSTALL SAS 2' to 4' down-flow of the coil
SUPPLY
PLENUM
GAS or
ELECTRIC
HEAT
COIL
RETURN
AIR
AIR FLOW
INSTALL SAS AFTER the COIL but BEFORE the BLOWER
HEAT PUMP (Standard Electric Aux.)
SUPPLY
PLENUM
ELECTRIC
(Auxiliary)
HEAT
COIL
RETURN
AIR
AIR FLOW
Standard GE or All Electric Equipment
Heat Pump Equipment
Reversing valve energized in COOLING
Reversing valve energized in HEATING
Operates Aux. Heat WITH compressor (HP Only)
Operates Aux. Heat WITHOUT compressor
2nd Stage Active (Normal Operation)
2nd Stage will not energize if only ONE zone open
Energizes fan after 90 second delay in heating
Energizes fan immediately with heating
Primary equipment controller (NORMAL)
Zone Expansion Mode Add 4-Zones to SmartZone
GAS/ELECT
HEAT PUMP
RVS. VLV O
B
NORMAL
DUAL FUEL
2
nd
STAGE
LOCKOUT
FAN GAS
ELECTRIC
SmartLink ZONES (1-4)
ZONES (5 8)
DIP SWITCHES
1
2
3
4
5
6
BOLD = DEFAULT
ECOJAY SmartZone
COM
Y1
Y2 (OPT.)
G
W1-EH
W2-O/B (OPT.)
RC
RH
COLOR (TYPICAL)
-- no standard
YELLOW
-- no standard
GREEN
WHITE
ORANGE
RED
RED
EQUIPMENT
24VAC (COMMON)
COMPRESSOR (STAGE 1)
COMPRESSOR (STAGE 2)
FAN (BLOWER)
HEAT (STAGE 1) or EMER. HEAT
HEAT (STAGE 2) or RVS. VALVE
24VAC - COOLING
24VAC - HEATING
ZONE 4 DAMPER
TERMINAL CAN BE
CONFIGURED AND
USED AS A FRESH
AIR DAMPER
CONTROL. SEE
NEXT PAGE FOR
DETAILS.
2-WIRE
POWER OPEN
SPRING CLOSE
DAMPER WIRING
USE 18 Gauge Solid Conductor Wire
USE 18 GAUGE Solid Conductor Wire
NOTE: For a HEAT PUMP System with
Emergency Heat: ONLY ZONE 1
Thermostat will have the ability to
energize Emergency Heat.
SmartZone
R
C
Y
G
W
O/B
COLOR (TYPICAL)
RED
-- no standard
YELLOW
GREEN
WHITE
ORANGE
THERMOSTAT
24VAC (HOT)
24VAC (COMMON)
COMPRESSOR
FAN
HEAT or EMERGENCY HEAT
REVERSING VALVE
THERMOSTAT WIRING
SmartZone will use time and temperature to automatically manage staging.
This accurate method of staging eliminates the need for multi-stage
thermostats. SmartZone is compatible with most all thermostats that have a
common connection or are battery powered / mechanical.
Gas/Electric
THERMOSTAT
C
R
G
Y
W
FUSE
FUSE SIZE
2A
3A
4A
TRANSFORMER VA
40
75
100
FUSE SIZE RULE OF THUMB
Heat Pump
THERMOSTAT
w/ EH
C
R
W2
OB
G Y
W1
EH
USE 18 GAUGE Solid Conductor
Wire and always install a field
supplied fuse as shown.
NOTE:
ALWAYS Disconnect
power to SmartZone while
making any wiring changes.
See previous page 2 for
transformer sizing requirements.
SMARTLINK
EASY WAY TO ADD MORE ZONES
SmartZone-4X ONLY
SEE BACK PAGE FOR DETAILS
INSTALLATION STEPS
Mount SmartZone enclosure (not pictured)
Install SUPPLY TEMP SENSOR
Wire DAMPERS to SmartZone
Set DIP SWITCHES on SmartZone
Wire THERMOSTATS to SmartZone
Wire SMARTLINK if applicable (ONLY 5 Zones or more)
Wire SmartZone 24VAC TRANSFORMER
Set THERMOSTAT TYPE if using Heat Pump
Wire EQUIPMENT to SmartZone
1
4 ZONE
(ZS4X)
ONLY
Push buttons for
adjusting HIGH and
LOW temp limits,
configuring
thermostat type and
FRESH AIR operation.
See next page for
detials.
Multiple dampers can be wired to each
zone as necessary based on duct
configuration. 40 VA PER ZONE MAX. (ie.
Four 10 VA Dampers or thirteen, 3 VA
dampers OR any combination adding up
to a total of less than 40VA)
Any 24VAC Damper can be used including
TWO-WIRE or THREE-WIRE Dampers.
4X
ZS4X
2.0
SmartZone
2
3
4
5
6
7
8
9
SmartZone
ecojay
- 2.0 -
ECOJAY SmartZone 2X & 4X Install Guide Rev 4.0 Copyright 2011-12-15 subject to change without notice
2
3
4
5
6
7
8
9

Related product manuals