Z-Wave Plus Command Class Notification
These notifications are sent unsolicited to the lifeline Association group.
Notification Type
Event
Cause
Smoke Alarm (0x01)
Smoke Detected, Unknown Location (0x02)
Smoke Alarm Sounding
Event Inactive (0x00)
Smoke Alarm Silent
CO Alarm (0x02)
Carbon Monoxide Detected, Unknown
Location (0x02)
CO Alarm Sounding
Event Inactive (0x00)
CO Alarm Silent
Home Security (0x07)
Tampering, Product Cover Removed (0x03)
Case Tampered
Event Inactive (0x00)
Case Restored to
Closed Position
Power Management
(0x08)
Replace Battery Soon (0x0A)
Battery is Getting Low
Replace Battery Now (0x0B)
Battery Needs
Replacing
Z-Wave Plus Command Class Basic
For backwards compatibility with older Z-Wave Plus Controllers, the Basic Command Class is supported in the following
manner. If either a smoke alarm or a CO alarm is detected, the lifeline nodes will receive an unsolicited Basic Report of
0xFF. When no more smoke or CO alarm sound detected, the lifeline nodes will receive an unsolicited Basic Report of
0x00. The device has no functionality mapped to receiving a Basic Set command, and does not control devices with a
Basic Set.
Z-Wave Plus Command Class Multi Level Sensor
The FireFighter has a temperature sensor built into the device and can be queried on a Wake Up Notification with a
Multi-Level Sensor Get command. The sensor supports reporting both in Celsius and Fahrenheit.