Sets the Minimum Off Time (MOT) delay before another heating/cooling cycle
can begin. Provides compressor short cycle protection. “Wait” is displayed on
screen when active.
Sets the maximum heating setpoint value.
Will not ramp or accept setpoints higher than this maximum
Sets the minimum cooling setpoint value
Sets the system blower delay off time after a heat call ends (fan purge)
Sets the system blower delay off time after a cool call ends (fan purge)
Sets the minimum separation between heating and cooling setpoints.
Note:
Attempts to lower cooling setpoint below the heating setpoint will PUSH the
heating setpoint down to maintain this separation. The same applies to setting
the heating setpoint above the cooling setpoint, it will PUSH the cooling set-
point up to maintain the setpoint delta separation
Sets the delta from setpoint that stage 1 heating starts
Sets the delta from setpoint that stage 1 heating stops. Stage 1 turns off at
setpoint + Delta Stage 1.
Sets the delta from setpoint that stage 2 heating starts
Sets the delay from setpoint that stage 2 heating stops. Stage 2 turns off at
setpoint + Delta Stage 2.
Sets the delta from setpoint that stage 3 heating starts
Sets the delta from setpoint that stage 3 heating stops.
Stage 3 turns off at setpoint + Delta Stage 3
Sets the delta from setpoint that stage 1 cooling starts.