Page 22 ECOM-D
10. Adjustments
In addition to the ECOM-D functions described previously, various ad-
justments can be made to the instrument.
From the main menu, select "Adjustments" and confirm with <En-
ter>.
A selection of modifiable parameters, adjustable ac-
cording to the application, is displayed.
Place the cursor on the desired line and press <En-
ter> to view or modify the adjustment. The modifia-
ble parameters are:
Unit (adjustment with arrow keys):
- Calculation of gas concentrations in:
- ppm = volume concentration (parts per million)
- mg/m
3
= mass concentration per volume unit
- mg/kWh (undiluted) = mass concentration per power unit
- mg/MJ (undiluted) = mass concentration per power unit
- ppm (undiluted) = volume concentration (parts per million)
- mg/m
3
(undiluted)
= mass concentration per volume unit
Undiluted:
Conversion of the gas concentration on selected reference oxygen:
- mg/kWh and mg/MJ are always calculated on 0% O
2
basis
- Conversion formula
O
2
reference
(for ppm and mg/m
3
- Input after pressing <Enter>):
- Input of O
2
reference value O
2 ref
E
ref
= E
meas
*
21 - O
2ref
21 - O
2meas
Einheit
Ref. O2
Fuel type
Air pressure
Set clock
Paper feed
Internal
Select :
