14. Technical Data
Parameter Range Principle
O
2
0 ... 21 vol-% Electrochemical
CO 0 ... 4000 ppm Electrochemical
NO (option) 0 ... 5000 ppm Electrochemical
NO
2
(option) 0 ... 500 ppm Electrochemical
SO
2
(option) 0 ... 5000 ppm Electrochemical
CO% (option) 4000 ... 63000 ppm Electrochemical
CO
2
0 ... CO
2max
Calculation
T-Gas 0 ... 500 °C NiCr/Ni
T-Air 0 ... 99 °C Semi-conductor
Differential pressure 0 ... +/- 100 hPa DMS bridge
Efficiency 0 ... 120 % Calculation
Losses 0 ... 99,9 % Calculation
Excess air 1 ... Calculation
CO undiluted (adjustable ref. O
2
) Calculated
Flue gas dew point Calculated
Op. Temp: 20-122°F
Power supply Charger 230 V / 50 Hz~; Accu 6 V / 3,8 Ah
Protocol printer integral; 58 mm paper width
Printout individually programmable
Indication graphic display; backlit
Dim. (W x H x D) 400 mm x 260 mm x 175 mm
Weight approx. 6 kg complete with sampling system
Subject to technical changes