7. Shut o feed water valve and restore water
supply to the site of installation. Ensure the
drinking water faucet is opened and start to
open the feed water valve slowly letting air
out of the system. After the air has escaped
adjust the feed water valve to a ow rate of
1 liter (1 quart) per minute.
8. Leave the drinking water faucet open for
30 minutes. Close the drinking water faucet
and inspect every connection for leaks. If
leaks are not detected, the lter is ready for
use.
Guide to using your Ecosoft lter
The lter is designed for treating cold water only!
Do not exceed the recommended water ow rate
of 1 liter (1 quart) per minute, or water quality will
deteriorate.
In case of prolonged downtime, perform
disinfection procedure rst before continuing to
use the system per guidelines on page 6.
Do not use disposable cartridges longer than
recommended service life (or exceed total water
amount).
Feed water quality may signicantly aect
cartridge capacity.
The manufacturer strongly recommends installing
a pressure regulator, if your water pressure may
exceed 5 bar (72 psi) at any time. Pressure surges
may also result from water supply interruption.