EasyManua.ls Logo

Ecosoft Robust - User Manual

Ecosoft Robust
28 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
ECOSOFT Robust
Reverse osmosis system
Installation and operation manual

Questions and Answers

  • Y
    yhessAug 18, 2025
    What to do if my Ecosoft Water Filtration System will not switch off?
    • J
      Jamie GarciaAug 19, 2025
      If your Ecosoft Water Filtration System won't switch off, even when the purified water faucet is closed and the pressure tank is full, the issue might be: * High pressure switch failure: Replace the high pressure switch and verify proper electrical contact. * Soiled membranes: Replace the membranes.
  • K
    keithsheaAug 21, 2025
    Why is the purified water flow rate lower than normal in my Ecosoft Water Filtration System?
    • D
      Deborah LopezAug 21, 2025
      A lower than normal purified water flow rate in your Ecosoft Water Filtration System can be due to several reasons: * Low feed water pressure: If the feed water operating pressure is below 2 bar, address any upstream pressure drop or consider installing a pressure booster pump. * Soiled prefilters: Replace the prefilters. * Soiled membranes: Replace the membranes. * Bent flexible tube: Inspect the tubing and straighten it if necessary.
  • J
    johnjohnsonAug 23, 2025
    What to do if my Ecosoft Water Filtration System keeps switching on and off?
    • A
      Amanda FloydAug 23, 2025
      If your Ecosoft Water Filtration System keeps switching on and off, it could be due to surges in feed water pressure just above the low pressure switch setting. Eliminate these pressure surges and check the supply water piping for any clogs or obstructions, removing them if found.
  • R
    Robert SchneiderAug 26, 2025
    What to do if my Ecosoft Water Filtration System will not switch on?
    • K
      Kathryn PetersonAug 26, 2025
      If your Ecosoft Water Filtration System won't switch on, possible causes include: * Feed valve or main shutoff valve is closed: Open all valves on supply water pipes, and check for any clogs or obstructions. * Low pressure switch failure: Replace the low pressure switch, and verify proper electrical contact.
  • A
    Angel MckinneyAug 28, 2025
    Why is the purified water hazy or cloudy from my Ecosoft Water Filtration System?
    • T
      Teresa RussellAug 28, 2025
      If the purified water from your Ecosoft Water Filtration System is hazy or cloudy but clears up after a few minutes, it is likely due to air bubbles trapped in the system. Some air may remain in the system for a few days after installation and will dissipate on its own. Also, air bubbles may appear if there's a significant temperature difference between the feed water and the ambient temperature.
  • H
    Holly BaldwinAug 30, 2025
    Why does purified water from my Ecosoft Water Filtration System have a taste or odor?
    • D
      Derek HillAug 30, 2025
      If the purified water from your Ecosoft Water Filtration System has a taste or odor, it could be due to: * Expired postfilter: Replace the postfilter. * Membrane preservative not fully flushed: Flush the RO system and discard all rinsewater. * Contamination of the system: Sanitize the system according to instructions. * Contamination of pressure tank: Sanitize the pressure tank according to instructions. Note that pressure tank may become contaminated if filters or membranes are used beyond their service life.
  • M
    Michael BaileySep 1, 2025
    What to do if my Ecosoft Water Filtration System is sending water to drain?
    • D
      Daniel WrightSep 1, 2025
      If your Ecosoft Water Filtration System has switched off but continues to send water to drain, it is likely due to a solenoid valve failure. Replace the solenoid valve and protect the system from debris and particulates if present in the feed water.
  • H
    hhernandezSep 4, 2025
    What to do if my Ecosoft Water Filtration System's pressure tank is not full?
    • K
      Kathryn CoxSep 4, 2025
      If the pressure tank of your Ecosoft Water Filtration System is not full when the system switches off, it could be because: * Tank bladder is overinflated: The pressure in the empty tank bladder must be within the specified range. Release some pressure if necessary. * Tank valve is closed: Check the tank valve position.
  • S
    Shelby SampsonSep 6, 2025
    Why is the recovery decreased significantly in my Ecosoft Water Filtration System?
    • N
      natalie06Sep 6, 2025
      If the recovery rate of your Ecosoft Water Filtration System has decreased significantly, the cause might be: * Soiled prefilters: Replace the prefilters. * Soiled membranes: Replace the membranes.
  • W
    washingtongabrielSep 8, 2025
    What to do if water is not discharged to drain when the Ecosoft Water Filtration System is on?
    • L
      Laura BrownSep 8, 2025
      If water is not being discharged to the drain when your Ecosoft Water Filtration System is on, it could be due to: * Clogged flow restrictor: Clean the flow restrictor or replace it if necessary. * Drain saddle not seated correctly: Install the drain saddle correctly.

Summary

1. APPLICATION

2. SPECIFICATIONS AND COMPONENTS

2.1 TECHNICAL SPECIFICATIONS

Details operational parameters, dimensions, and electrical requirements of the system.

2.3 SYSTEM COMPONENTS

3. INSTALLATION DIAGRAMS

4. INSTALLATION STEPS

4.1. INSTALLATION CONDITIONS AND PACKAGE COMPLETENESS CHECK

Checks required utilities and ensures all system components are present before installation.

4.2. INSTALLATION

Detailed procedure for physically installing the reverse osmosis system.

5. POST-INSTALLATION

6. OPERATION

6.2. FILTER REPLACEMENT

6.3 MEMBRANE REPLACEMENT

7. SANITIZATION

8. TROUBLESHOOTING

Standard Robust RO system installation procedure

Ecosoft Robust Specifications

General IconGeneral
Filtration Stages5
TypeReverse Osmosis
Storage Tank Capacity8 L
Operating Pressure40-80 psi
Housing MaterialPlastic
Filter Life (pre-filters)6 months
Filter Life (membrane)24 months
Weight15 lbs