EasyManuals Logo

Ecosoft Robust User Manual

Ecosoft Robust
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #7 background imageLoading...
Page #7 background image
Instruction manual for ECOSOFT Robust reverse osmosis system | 7
This manual is the intellectual property of, and copyrighted by ECOSOFT SPC LLC. Copying and reprinting is forbidden. © 2015
2. SPECIFICATIONS AND COMPONENTS
2.1 TECHNICAL SPECIFICATIONS
Parameter
Value
1 Purified water flow rate
@ 25 °C, 1000 mg/l total dissolved solids feed water
55…60 l/h
2 Feed water flow rate 110…130 l/h
3 Concentrate flow rate 55…65 l/h
4 Inlet water pressure 2,0…5,0 bar*
5 Operating pressure in membrane array 5,0…7,0 bar
6 Pressure in tank bladder (when used with pressure tank) 0,4…0,6 bar
7 Feed water temperature +4… +30 °C**
8 Ambient air temperature +5…+40 °C**
9 Connection to water mains ½″ thread
10
Overall dimensions, H × W × D (base model) 420×220×425
mm
11
Weight (base model) 6 kg
12
Electrical rating 230 V, 50 Hz
13
Power consumption, max. 80 W
14
Ingress protection rating IP 54
* If pressure of water in your system does not meet requirement, install a pressure booster pump to raise it.
If water pressure exceeds the upper limit, install a pressure regulator before the Robust system.
** Using the Robust system with feed water temperature between +20 and +30 °С produces a lower
rejection rate and higher flow rate, which yields higher TDS of purified water. Using the system with feed
water above +30 °С is advised against.
2.2 FEED WATER REQUIREMENTS*
Parameter
**
1
pH
6,5…
8,5
2 Total dissolved solids (TDS) < 1500 mg/l
3
Hardness
< 30 °dH (500
mg
CaCO
/l)
4
Residual chlorine
< 0,5 mg/l
5 Iron < 0,3 mg/l
6 Manganese < 0,1 mg/l
7
Chemical oxygen demand
< 5 mg O
2
/l
8
Total microbial count
< 100 CFU/ml
9
E. coli none
* If feed water quality does not meet specified requirements, membrane and filter service life may decrease.
** If aiming to purify raw water (well water/ground water etc), it is recommended to carry out detailed
water analysis. If any constituents exceed the above limitations, it is advisable to install a special filter
upstream of your reverse osmosis system. Consult professional water treatment specialist for proper
selection of an appropriate filter for your water.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ecosoft Robust and is the answer not in the manual?

Ecosoft Robust Specifications

General IconGeneral
BrandEcosoft
ModelRobust
CategoryWater Filtration Systems
LanguageEnglish

Related product manuals