2. SPECIFICATIONS AND COMPONENTS
2.1 TECHNICAL SPECIFICATIONS
Parameter
Value
1 Purified water flow rate
@ 25 °C, 1000 mg/l total dissolved solids feed water
55…60 l/h
2 Feed water flow rate 110…130 l/h
3 Concentrate flow rate 55…65 l/h
4 Inlet water pressure 2,0…5,0 bar*
5 Operating pressure in membrane array 5,0…7,0 bar
6 Pressure in tank bladder (when used with pressure tank) 0,4…0,6 bar
7 Feed water temperature +4… +30 °C**
8 Ambient air temperature +5…+40 °C**
9 Connection to water mains ½″ thread
10
Overall dimensions, H × W × D (base model) 420×220×425
mm
11
Weight (base model) 6 kg
12
Electrical rating 230 V, 50 Hz
13
Power consumption, max. 80 W
14
Ingress protection rating IP 54
* If pressure of water in your system does not meet requirement, install a pressure booster pump to raise it.
If water pressure exceeds the upper limit, install a pressure regulator before the Robust system.
** Using the Robust system with feed water temperature between +20 and +30 °С produces a lower
rejection rate and higher flow rate, which yields higher TDS of purified water. Using the system with feed
water above +30 °С is advised against.
2.2 FEED WATER REQUIREMENTS*
Parameter
**
1
pH
6,5…
8,5
2 Total dissolved solids (TDS) < 1500 mg/l
3
Hardness
< 30 °dH (500
mg
CaCO
/l)
4
Residual chlorine
< 0,5 mg/l
5 Iron < 0,3 mg/l
6 Manganese < 0,1 mg/l
7
Chemical oxygen demand
< 5 mg O
2
/l
8
Total microbial count
< 100 CFU/ml
9
E. coli none
* If feed water quality does not meet specified requirements, membrane and filter service life may decrease.
** If aiming to purify raw water (well water/ground water etc), it is recommended to carry out detailed
water analysis. If any constituents exceed the above limitations, it is advisable to install a special filter
upstream of your reverse osmosis system. Consult professional water treatment specialist for proper
selection of an appropriate filter for your water.