Opportunity 30A/100AH, OP30-01 This curve is designed to
opportunity charge a battery in the vehicle during break, lunch and
shift change periods for 2 shift applications where the level of
discharge is typically at or below about 1.37 times the 80% rating of
the battery (1.37 EBU) per day.
Opportunity 35A/100AH, OP35-01 This curve is designed to
opportunity charge a battery in the vehicle during break, lunch and
shift change periods for 2 shift applications where the level of
discharge is typically at or below about 1.49 times the 80% rating of
the battery (1.49 EBU) per day.
Opportunity 40A/100AH, OP40-01 This curve is designed to
opportunity charge a battery in the vehicle during break, lunch and
shift change periods for 2 or 3 shift applications where the level of
discharge is typically at or below 1.60 times the 80% rating of the
battery (1.60 EBU) per day.
NOTICE: OPPORTUNITY CHARGING APPLICATIONS
REQUIRE THOROUGH INVESTIGATION INTO THE ACTUAL
BATTERY USAGE, CHARGE TIME AVAILIABLE AND AMBIENT
TEMPERATURE. THE NUMBERS SUGGESTED ABOVE ARE TYPICAL
IN NATURE AND DO NOT IMPLY ANY WARRANTY OR GUARANTEE
OF OPPORTUNITY CHARGING APPLICATION SUCCESS.