EasyManua.ls Logo

ECTIVE MI Series - Operating conditions; Everything at a glance; Efficiency range; Idle current consumption

ECTIVE MI Series
48 pages
Go to English
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
[
ECTIVE
®
POWER INVERTER – MI-/TMI-SERIES
]
36
Operating conditions
Everything at a glance
Power indication proportional to the
continuous output indicated in
120 % – 150 % for 10 seconds
150 % – 200 % for 2 seconds
Switching time UPS (TMI Series) <16 ms
AC voltage 230 V
AC voltage fluctuation: max. 10%
Frequency: 50 Hz ± 1%
Waveform Modified sine wave
Battery types Wet, AGM, GEL, Li-Ion (only with BMS)
Efficiency range*
system voltage Efficiency
12 V 85 % – 89 %
24 V 86 % – 90 %
48 V 87 % – 91 %
* Actual efficiencies depend on the type of consumer and load.
For example, the inverter typically has the highest efficiency at a load of approx. 70 %.
Idle current consumption MI-/TMI-series
Model MI-/TMI- 12 V 24 V 48 V
30 approx. 0,30 A approx. 0,15 A approx. 0,08 A
60 approx. 0,45 A approx. 0,22 A approx. 0,11 A
100 approx. 0,50 A approx. 0,25 A approx. 0,13 A
150 approx. 0,65 A approx. 0,33 A approx. 0,17 A
200 approx. 0,70 A approx. 0,35 A approx. 0,18 A