ECTIVE
®
POWER INVERTER – MI-/TMI-SERIES
]
36
Operating conditions
Everything at a glance
Power indication proportional to the
continuous output indicated in
120 % – 150 % for 10 seconds
150 % – 200 % for 2 seconds
Switching time UPS (TMI Series) <16 ms
AC voltage 230 V
AC voltage fluctuation: max. 10%
Frequency: 50 Hz ± 1%
Waveform Modified sine wave
Battery types Wet, AGM, GEL, Li-Ion (only with BMS)
Efficiency range*
system voltage Efficiency
12 V 85 % – 89 %
24 V 86 % – 90 %
48 V 87 % – 91 %
* Actual efficiencies depend on the type of consumer and load.
For example, the inverter typically has the highest efficiency at a load of approx. 70 %.
Idle current consumption MI-/TMI-series
Model MI-/TMI- 12 V 24 V 48 V
30 approx. 0,30 A approx. 0,15 A approx. 0,08 A
60 approx. 0,45 A approx. 0,22 A approx. 0,11 A
100 approx. 0,50 A approx. 0,25 A approx. 0,13 A
150 approx. 0,65 A approx. 0,33 A approx. 0,17 A
200 approx. 0,70 A approx. 0,35 A approx. 0,18 A