SD3 Series Ultrasonic Pocket Doppler User Manual EMC Information
- 38 -
a Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and
land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted
theoretically with accuracy. To assess the electromagnetic environment due to fixed RF transmitters, an
electromagnetic site survey should be considered. If the measured field strength in the location in which
the SD3 Series Ultrasonic Pocket Doppler is used exceeds the applicable RF compliance level above, the
SD3 Series Ultrasonic Pocket Doppler should be observed to verify normal operation. If abnormal
performance is observed, additional measures may be necessary, such as reorienting or relocating the SD3
Series Ultrasonic Pocket Doppler.
b Over the frequency range 150 kHz to 80 MHz, field strengths should be less than 3 V/m.
c The ISM (industrial, scientific and medical) bands between 0,15 MHz and 80 MHz are 6,765 MHz
to6,795 MHz; 13,553 MHz to 13,567 MHz; 26,957 MHz to 27,283 MHz; and 40,66 MHz to 40,70 MHz.
The amateur radio bands between 0,15 MHz and 80 MHz are 1,8 MHz to 2,0 MHz, 3,5 MHz to 4,0 MHz,
5,3 MHz to 5,4 MHz, 7 MHz to 7,3 MHz, 10,1 MHz to 10,15 MHz, 14 MHz to 14,2 MHz, 18,07 MHz to
18,17 MHz,21,0 MHz to 21,4 MHz, 24,89 MHz to 24,99 MHz, 28,0 MHz to 29,7 MHz and 50,0 MHz to
54,0 MHz.
Table-Test specifications for ENCLOSURE PORT IMMUNITY to RF wireless communications
equipment
Test
Frequency
(MHz)
Brand a)
(MHz)
Service a)
Modulation
b)
Maximum
Power(W)
Distance
(m)
IMMUNITY
TEST LEVEL
(V/m)
385
380-390
TETRA 400
Pulse
modulation
b) 18Hz
1.8
0.3
27
450
430-470
GMRS 460,
FRS 460
FM C)
2
0.3
28
±5 kHz
deviation
1kHz sine
710
704-787
LTE Brand
13, 17
Pulse
modulation
b) 217 Hz
0.2
0.3
9
745
780
810
800-960
GSM
800/900,TE
TRA 800,
iDEN 820,
CDMA 850,
LTE Band 5
Pulse
modulation
b) 18 Hz
2
0.3
28
870
930
1720
1700-1990
GSM 1800;
CDMA
1900; GSM
1900;
DECT; LTE
Band 1, 3,
4,25;
UMTS
Pulse
modulation
b) 217 Hz
2
0.3
28
1845
1970