EDAN SE-301 Specifications

General IconGeneral
ECG Channels3 channels
Lead Configuration12-lead
Power SupplyAC 100-240V, 50/60 Hz
BatteryRechargeable lithium battery
PrintingThermal printer
Input Impedance≥ 50 MΩ
Type3 Channel ECG
DisplayLCD
Recording Speed25mm/s, 50mm/s
Battery Life≥ 3 hours continuous working under optimal state
Paper Size80 mm (width)
Frequency Response0.05Hz - 150Hz
CMRR> 100 dB
Recording ModeAuto, Manual
FiltersAC, EMG, DFT
Data StorageInternal memory
External OutputUSB, LAN
ParametersECG
SpO2Not available
NIBPNot available
TEMPNot available

Summary

Chapter 1 Safety Guidance

1.1 Indications for Use/Intended Use

Details the intended use of the 3-Channel Electrocardiograph for acquiring ECG signals from adult and pediatric patients.

1.2 Warnings and Cautions

Provides crucial information for safe and effective operation of the electrocardiograph, covering potential dangers.

1.2.1 Safety Warnings

Lists critical safety warnings regarding equipment operation, installation, authorized personnel, and electrical hazards.

1.2.2 Lithium Battery Care Warnings

Outlines precautions and warnings for the safe handling, charging, and replacement of the lithium battery.

1.2.3 General Cautions

Presents general cautionary advice for operating the electrocardiograph, including environmental and interference considerations.

1.3 List of Symbols

Explains the meaning of various symbols used throughout the user manual for identification and warnings.

Chapter 2 Introduction

2.1 Top Panel

Describes the components and functions located on the top panel of the electrocardiograph, including recorder and buttons.

2.2 Bottom Panel

Details the features and information found on the bottom panel of the device, specifically the battery compartment indicator.

2.3 Right Panel

Identifies and explains the controls and indicators on the right side, including the patient cable socket and power key.

2.4 Back Panel

Illustrates and describes the ports and connections available on the back panel, such as USB and Net ports.

Chapter 3 Operation Preparations

3.1 Loading/Replacing Recorder Paper

Provides step-by-step instructions for loading and replacing the thermal recorder paper correctly.

3.2 Preparing the Patient

Guides on how to prepare the patient for ECG recording, including instructions and skin cleaning.

3.3 Connecting the Patient Cable to the Electrocardiograph and Electrodes

Explains the procedure for correctly connecting the patient cable to the device and electrodes for accurate readings.

3.4 Attaching Electrodes to the Patient

Details the process of attaching electrodes to the patient for ECG acquisition, covering reusable and disposable types.

3.4.2 Disposable Electrodes

Describes the use, placement, and connection of disposable electrodes with alligator clips for ECG recording.

3.5 Inspection Before Power On

Lists essential checks for environment, power supply, patient cable, electrodes, and paper before powering on.

Chapter 4 Sampling and Printing ECG

4.1 Entering Patient Information

Explains how to manually enter patient details, including settings for pacemaker detection, for ECG recording.

4.2 Printing ECG Reports

Outlines the steps and procedures for printing ECG reports from the device, including work mode selection.

4.3 Sample ECG Reports

Presents examples of ECG reports generated in AUTO mode, detailing wave configurations and measurement information.

4.3.2 PDF Report

Details the format and content of PDF ECG reports, including parameters like paper speed and gain.

Chapter 5 Managing ECG Records

5.1 Transmitting ECG Records to the PC

Guides on how to transfer ECG records from the device to a personal computer using network or Wi-Fi.

5.2 Copying ECG Records between the ECG Machine and External Memory

Explains the process of copying ECG data between the device and external storage media like USB drives.

5.3 Deleting Patient Records

Describes how to delete individual patient records or all records from the device's file manager.

5.4 Printing a Patient Record in the File Manager screen

Details how to print individual patient records directly from the file manager interface using a connected printer.

Chapter 6 Settings

6.1 Work Mode

Allows selection of different operating modes for ECG sampling and recording, such as Pre-Sample or Real-time.

6.2 Filter

Explains the various filter options (AC, DFT, EMG, Lowpass) available to improve ECG signal quality.

6.3 Record Info Setup

Configures settings related to recording information, such as print out, speed, gain, and auto record style.

6.8 Date&Time Setup

Instructions for setting the device's date and time, crucial for accurate record keeping and reporting.

6.9 System Maintenance

Covers system maintenance tasks like importing/exporting settings, backup, and loading factory defaults.

6.10 Other Setup

Provides options for configuring institution name and demo mode settings for the electrocardiograph.

6.5 Transmission Setup

Configures network settings, IP addresses, and transmission modes for sending ECG data to a PC.

6.6 Lead Setup

Allows customization of lead sequences (Standard/Cabrera) and lead off hints for ECG acquisition.

6.7 File Setup

Manages file saving options, formats (DAT, PDF, SCP), deletion after transmission, and memory management.

6.11 Advanced Setup

Accesses device information, performs system tests, and activates purchased advanced functions.

Chapter 7 Hint Information

Chapter 8 Troubleshooting

1) Operating Problems

Addresses common issues encountered during the operation of the electrocardiograph, such as saving data without printing.

2) Printing Problems

Provides solutions for various printing-related issues, such as paper jams, double impressions, and error messages.

3) Transmitting Problems

Offers troubleshooting steps for issues related to ECG data transmission, including connection and PC software problems.

4) Main Unit Problems

Covers problems concerning the main unit, including lead-off alerts and touch screen sensitivity issues.

Chapter 9 Cleaning, Care and Maintenance

9.1 General Points

General guidelines for keeping the electrocardiograph and accessories clean and maintained to prevent damage.

9.2 Cleaning

Details the cleaning procedures for the main unit, patient cable, and reusable electrodes using approved agents.

9.2.1 Cleaning the Main Unit

Specific instructions for cleaning the exterior of the main electrocardiograph unit, including wiping and drying.

9.2.2 Cleaning the Patient Cable

Step-by-step guide for cleaning the patient cable using a soft cloth and cleaning solution.

9.2.3 Cleaning the Reusable Electrodes

Procedures for cleaning reusable electrodes, including removing residual gel and wiping suction bulbs/clamps.

9.3 Disinfection

Explains the recommended methods for disinfecting the electrocardiograph and its accessories using ethanol or isopropanol.

9.3.1 Disinfecting the Main Unit

Specific instructions for disinfecting the main unit of the electrocardiograph, requiring power off.

9.3.2 Disinfecting the Patient Cable

Instructions for disinfecting the patient cable, involving wiping with a disinfectant solution and air drying.

9.3.3 Disinfecting the Reusable Electrodes

Guidelines for disinfecting reusable electrodes, including wiping with disinfectant and air drying.

9.4 Care and Maintenance

Covers general care and maintenance practices for the device, including battery management and recorder paper storage.

9.4.3 Maintenance of the Main Unit, the Patient Cable and Electrodes

Outlines safety checks and maintenance procedures for the main unit, patient cable, and electrodes to be performed periodically.

Chapter 10 Accessories

Chapter 11 Warranty and Service

11.1 Warranty

Details the warranty terms and conditions for EDAN products, including coverage and exclusions.

11.2 Contact information

Provides contact details for EDAN service department and local distributors for maintenance and inquiries.

Appendix 1 Technical Specifications

A1.1 Safety Specifications

Lists the safety standards (IEC 60601 series) and specifications the electrocardiograph complies with.

A1.2 Environment Specifications

Specifies the environmental conditions for transport, storage, and operation, including temperature and humidity.

A1.3 Physical Specifications

Details the physical dimensions, weight, and display specifications of the electrocardiograph.

A1.4 Power Supply Specifications

Outlines the power requirements and specifications for mains supply and the built-in lithium battery pack.

A1.5 Performance Specifications

Lists the performance characteristics of the electrocardiograph's recording unit, HR recognition, and ECG unit.

Appendix 2 EMC Information

Electromagnetic emissions

Provides guidance on electromagnetic emissions from the electrocardiograph and its intended electromagnetic environment.

Electromagnetic immunity

Details the electromagnetic immunity standards and guidance for the electrocardiograph in various environments.

Appendix 3 Abbreviation

Related product manuals