E-2ECGC-PL-0711A
Printed in USA
JWA ©2011
Page 29
BALDOR CAT. NO. L3605T-50
2.0 H.P., 1 PHASE, 50 HERTZ, 1425 RPM,
110/220 VOLT, 20/10 FULL LOAD AMPS
ILLUSTRATION 19:
MOTOR WIRING DIAGRAM FOR 2 & 3 HP BALDOR
BALDOR CAT. NO. L3609T
3.0 H.P., 1 PHASE, 60 HERTZ, 1725 RPM,
115/230 VOLT, 28/14 FULL LOAD AMPS
(230V, 14A RECOMMENDED)
0
.---------------------
1-BLU
--;:::::=:::::::,,,,...,=---------2-WHT
---------"',--------3-0RG
A
PHASE
r---
7
I
,-----------
L---.J
'-
T~lJl.\'Jlt}-A;~----------
-----
J-BRN
----------------~.---8-RED
E
CENT
SWITCH
ELEC
CAP
OIL
CAP
.-----------1--5-BLK
B
PHASE
WHT/GRY
WHT/GRY
CD0055
LINE
A
LINE
B
JOIN
HIGH
STD
1
4,5
2,3,8
HIGH
OPP
1 4,8 2,3,5
LOW
STD
1,3,8 2,4,5 -
LOW
OPP
1,3,5
2,4
,8
-
NOTES:
1.
STANDARD
ROTATION
IS
CCW
FACING
END
OPPOSITE
SHAFT
EXTENSION
.
2.
OPTIONAL
THERMOSTAT
IS
PROVIDED
WHEN
SPECIFIED.
3.
MULTIPLE
CAPACITORS
ARE
CONNECTED
IN
PARALLEL
UNLESS
OTHERWISE
SPECIFIED.
4.
LEAD
COLORS
ARE
OPTIONAL
.
LEADS
MUST
ALWAYS
BE
NUMBERED
AS
SHOWN.
n
a
t-R-Ev-
.
-DE-s-c,-R-E_vi_sE_T_o_s_H_ow-oP-T-10-NA_L_c_oL-o-Rs----------~---B-A_L_D_O_R
__
E_L_E_C_T_R_I_C
__
C_o_.
----i
~
REV
. L
TR
: D
BY
:
JLP
REVISED
:
04/08/99
1:
17
TDR:
0178636
U1
MDL
: -
c;;c;;oom
FILE
: AAA00007414
MTL:
-
TYPE
LC,
DV,
REV,
6
LEADS
I 3 •l3•J
A Division
of
Equipment Development Company, Inc.
Go to Discount-Equipment.com to order your parts