IMPORTANT!
For a perfect result, the UV lamp must be placed close to the product (3-6 mm distance to the
product) and the photocell for the UV lamp must be positioned at the height of the lamp!
Safety Notes
• Do not look directly to the working UV lamp; if possible please wear UV light protection
goggles during operation.
• UV lamp could reach high temperature, do not touch the UV lamp directly to avoid burn.
• Keep all vent clear and not blocked to ensure the cooling system function properly.
• Do not irradiate the same area of the substrate/objector production line for too long to avoid
damage caused by high temperature.
• Keep UV lamp at least 25 cm away from the print head to avoid illumination onto the print
head nozzle and clog the nozzle.
• Over curing will powderize the UV ink and could reduce adhesion.
• Under curing will result in ink not fully dried and reduced adhesion.
Technical Specification
Power adapter: AC 100–240 V, 50/60 Hz