Page 35
IMPORTANT!
For a perfect result, the UV lamp must be placed close to the product (3-6 mm distance to the
product) and the photocell for the UV lamp must be positioned at the height of the lamp!
Safety Notes
Do not look directly to the working UV lamp; if possible please wear UV light protection
goggles during operation.
UV lamp could reach high temperature, do not touch the UV lamp directly to avoid burn.
Keep all vent clear and not blocked to ensure the cooling system function properly.
Do not irradiate the same area of the substrate/objector production line for too long to avoid
damage caused by high temperature.
Keep UV lamp at least 25 cm away from the print head to avoid illumination onto the print
head nozzle and clog the nozzle.
Over curing will powderize the UV ink and could reduce adhesion.
Under curing will result in ink not fully dried and reduced adhesion.
Technical Specification
Control Unit
Power supply
Power adapter: AC 100240 V, 50/60 Hz
Maximum Output Power
320 W
UV Lamp
Wavelength
395 nm
Peak Irradiance
12 W / cm²
Curing Area
25 x 36 mm
Maximum Power
190 W