INSTALLATION INSTRUCTIONS
IMPORTANT REQUIREMENTS
Oven installation must comply with local codes or, if local codes do not exist, with the National
Fuel Gas Code, ANSI Z223.1/NFPA 54 OR Natural Gas Installation Code, CAN/CGA-B149.1, or
the Propane Gas Installation Code, CAN/CSA-B149-2, as applicable.
This appliance must be electrically grounded in accordance with local codes, or if local codes
do not exist, with the National Electrical Code, ANSI/NFPA 70. OR with the Canadian Electrical
Code, CSA C22.2.
When this appliance is installed with casters, it must be installed with the casters supplied, a
connector complying with ANSI Z21.69 / CAN/CGA-6.16, a quick-disconnect device complying
with ANSI Z21.41, and a mechanism to limit movement of the appliance without straining the
connector or its associated piping system. This quick-disconnect device must not exceed 1.5
meters in length.
The gas supply tubing or hose shall comply with the national requirements in force and shall
be periodically examined and replaced as necessary.
This appliance and its individual manual shutoff valves must be disconnected from the gas
supply piping system during any pressure testing of gas supply piping at pressures exceeding
1/2 psi (3.5 kPa).
The installer of this oven must contact local building and fire officials concerning inspections
and installation requirements of this oven and its ventilation system.
Unless otherwise stated, parts protected by the manufacturer or the authorized agent shall not
be adjusted by the installer.
In the event this appliance is to be converted to a gas type other than which it was originally
adjusted for, contact manufacture or authorized agent for the appropriate conversion kit.
(correct orifice, correct appliance decal, and instructions)