EasyManua.ls Logo

EDI SSM-LE Series User Manual

Default Icon
33 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
THIS MANUAL CONTAINS TECHNICAL INFORMATION FOR THE SSM-6LE, SSM-
6LEip, SSM-6LEC, SSM-12LE, SSM-12LEip, and SSM-12LEC SERIES SIGNAL
MONITOR.
REVISION: MARCH 2012
pn 888-1216-002
SSM-LE Series
NEMA TS-1
Enhanced Signal Monitor
Operations Manual

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the EDI SSM-LE Series and is the answer not in the manual?

EDI SSM-LE Series Specifications

General IconGeneral
TypeSound Level Meter
InputMicrophone
DisplayLCD
PowerBattery
Resolution0.1dB
Power Supply9V battery
Measurement Range30 dB to 130 dB
Operating Temperature0°C to 40°C
Operating Humidity10% to 90% RH

Summary

General Information

Product Description and Capabilities

Details the SSM-LE series signal monitors, their functions, features, and NEMA compliance.

ECcom Software Interface

Details the EDI ECcom software for system interface, event logs, and signal sequence logs.

Flashing Yellow Arrow (FYA) Monitoring

Explains FYA movement monitoring and its fault coverage for traffic signals.

Standard NEMA Functions

Conflict Monitoring

Detects simultaneous active conflicting signals and triggers a fault.

Red Fail Monitoring

Monitors for the absence of signal voltage on all inputs of a channel.

DC Voltage Monitoring

Monitors +24Vdc supplies and Controller Voltage Monitor (CVM) inputs.

+24VDC Supply Monitoring

Monitors the voltage of two +24Vdc cabinet supplies.

Controller Voltage/Fault Monitor Input

Monitors the Controller Unit Voltage Monitor (CVM) output.

Power Failure Detection

Detects low AC LINE voltage and suspends fault monitoring.

Enhanced Features

Dual Indication Monitoring

Detects simultaneous active combinations of two signal inputs on a channel.

Minimum Yellow Clearance Monitoring

Verifies the Yellow Change interval meets the minimum clearance time.

External Watchdog Monitoring

Monitors an external watchdog output for changes in state.

Internal Diagnostics

Details the self-check diagnostic capabilities for correct operation.

Recurrent Pulse Detection

Detects intermittent or pulsing faults that normal algorithms might miss.

Flashing Yellow Arrow (FYA) Monitoring

Monitors traffic signal approaches using FYA movement, with fault conditions.

Basic FYA Mode Configuration

Details wiring and fault conditions for the basic FYA mode.

Compact FYAc Mode Configuration

Explains wiring and fault conditions for the compact FYAc mode.

ECcom Interface and Reporting

EDI ECcom Monitor Reports

Describes the interface with ECcom software for status and event logs.

Installation and Configuration

Permissive Channel Programming

Describes how to program permissive or compatible channel configurations using wire jumpers.

Unit Option Programming

Configuration of various unit options via front panel switches.

Flashing Yellow Arrow Monitor Setup

Specifies channel groups for Protected Green Arrows in FYA modes.

Technical Specifications

Electrical Specifications

Details power requirements and AC/DC voltage monitor thresholds.

Power Requirements

Specifies operating line voltage, frequency, and power consumption.

AC Voltage Monitor Specifications

Lists NEMA and LEDguard voltage thresholds for signal detection.

Power Fail Monitor Specifications

Specifies dropout and restore voltage levels for power failure detection.

DC Voltage Monitor Specifications

Lists fault and no-fault voltage levels for +24VDC monitors.

Timing Functions

Details timing parameters for various fault conditions and operations.

Wiring Assignments

SSM-12LE Harnessing Connectors

Details the MS-A and MS-B connector pin terminations for the SSM-12LE.

SSM-6LE Harnessing Connectors

Details the MS-A connector pin terminations for the SSM-6LE.

Ethernet LAN Port Configuration

Details network parameter configuration for the Ethernet port.