- 14 -
ENGLISH
Dear Sir or Madam,
thank you for choosing our Iris stove.
Before using your stove, please read this booklet carefully so that you may exploit all its features to the full in complete safety.
Please remember that the 1st ignition must be carried out by the dealer, which verifies the installation and completes the guarantee.
The manufacturer cannot be held liable for any damage deriving from stove use following incorrect installation, incorrect maintenance
or misuse.
SAFETY INFORMATION
The stove is designed to heat the room it is installed in by radiation and by air movement from the front grilles. The heat is genera-
ted by automatic pellet combustion in the •rebox.
The only risks which may derive from use of the stove are linked with non-compliance with the installation instructions, direct
contact with live electrical parts (inside) or with the •re or hot parts (glass, pipes and hot air outlet), and the introduction of
foreign substances. Only use pellets as fuel.
If components fail, the stove is •tted with safety devices which turn it off. This must be allowed to happen without interference.
For correct operation, the stove must be installed in compliance with the instructions on page 16 and the door must not be
opened during operation: combustion is managed automatically so no manual operations are needed.
Never put foreign substances in the •rebox or hopper.
Do not use !ammable products to clean the smoke duct.
Firebox and hopper components must only be cleaned using a vacuum cleaner.
The glass must be cleaned when COLD with a special product (e.g. GlassKamin) and cloth. Do not clean when hot.
Make sure the stove is installed and ignited by a quali•ed dealer, which must also complete the guarantee and take responsibility
for correct installation.
During stove operation, the outlet pipes and door reach high temperatures.
Do not keep objects which are not able to withstand heat in the immediate vicinity of the stove.
NEVER use liquid fuels to light the stove or rekindle the embers.
Do not block ventilation openings in the room where the stove is installed or air inlets in the stove itself.
Do not wet the stove, and do not put wet hands near electrical parts.
Do not •t reducers on the smoke outlet pipes.
The stove must be installed in a suitable place as regards •re regulations, and provided with all the facilities (power supply and
outlet) it requires for correct operation.
Before carrying out any maintenance, disconnect the device from the mains power supply.
Question and Answer IconNeed help?

Do you have a question about the EdilKamin IRIS and is the answer not in the manual?

EdilKamin IRIS Specifications

General IconGeneral
Nominal Power Output8 kW
Weight120 kg
Flue Outlet Diameter150 mm
Fuel TypeWood
Heating Power (min)3 kW
Heating Power (max)10 kW
Log Length33 cm

Summary

Safety Information and Precautions

Fuel Notes and Pellet Quality

Pellet Specifications and Quality

Details on recommended pellet types, characteristics, and indicators of poor quality.

Stove Safety Devices

Device Functions and Tripping Points

Overview of safety devices like Thermocouple, Air Flow Sensor, and Safety Thermostat.

Assembly and Installation Guide

Safety Distances and Air/Smoke Ducts

Critical safety distances, air intake specifications, and smoke outlet installation guidelines.

Control Interface and Operation

Stove Operation Procedures

Starting the Stove

Procedure for initiating the stove's automatic combustion sequence using the ON/OFF key.

Ignition and Startup

Automatic Ignition Procedure

Detailed steps for automatic ignition, including display messages and flame appearance.

Stove Shutdown

Weekly Time Programmer

Problem Advice and Troubleshooting

Common Issues and Solutions

Table listing common problems, their causes, and suggested solutions for stove operation.

Shutdown Error Codes Explained

Explanation of error codes (H1-H7) displayed upon stove shutdown and how to address them.

Detailed Troubleshooting Steps

In-depth analysis of specific shutdown causes like low pressure, motor failure, and ignition failure.

Flame Appearance Issues

Troubleshooting steps when flames do not appear or appear with an 'AF' error code.

Servicing and Maintenance