Preventive maintenance schedule
The following checks should be carried out to ensure safe operation and long service life.
This is a guide only and may change due the harshness of the process.
Action
Normal
Medium
Harsh
Check the oil level and fill the gearbox with the
oil, if necessary.
Daily
Daily
Daily
Remove the air filter elements and inspect.
Replace damaged or heavily contaminated
elements.
Monthly
Monthly
Weekly
Check for possible air and oil leakages
Check coupling and fan
Inspect the pipe lines and connections
Replace the air filter elements
4000 hrs.
2000 hrs.
1000 hrs.
Inspect and clean claws
Replace O-rings
Check pressure and temperature readings
Check operation of cooling fans of converter and
clean heat sink
Check and clean cooling fan assembly
Change oil
* (1)
20000 hrs
(2)
10000 hrs
(2)
5000 hrs
(2)
Replace lip seal assembly
20000 hrs.
20000 hrs.
20000 hrs.
Element overhaul
48000 hrs.
24000 hrs.
12000 hrs.
Clean damper
Change spring inlet valve
Change coupling
Consult Edwards for the internal cleaning
guidelines.
When necessary.
(1) Or after 4 years whichever comes first.
(2) Only use synthetic oil.
* In medium and harsh applications, an optional 500 hrs oil sample is recommended.
* For overpressure pump, oil change intervals are different.
CAUTION
Any leakage should be attended immediately. Damaged hoses or flexible joints must be replaced.
CAUTION
We recommend to monitor the oil condition through the sight glass and to change the oil when it becomes
discolored. Not changing oil in time may result in failure of the pump.