EasyManua.ls Logo

Edwards EDS 065

Edwards EDS 065
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6996 0223 96 Issue A
© Edwards Limited 2016. All rights reserved. Page 41
Edwards and the Edwards logo are trademarks of Edwards Limited.
8 TECHNICAL DATA
8.1 Reference conditions and limitations
Reference conditions
Unit
Relative humidity
%
0
Air inlet temperature
°C
20
°F
68
Exhaust back pressure
mbar(g)
0
psi
0
Ambient barometric pressure
mbar(a)
1013
psi
14.7
Limitations
Unit
Minimum ambient temperature
°C
0
°F
32
Maximum ambient temperature
°C
40
°F
104
Minimum allowable inlet temperature
°C
0
°F
32
Maximum allowable inlet temperature
°C
40
°F
104
Maximum (absolute) inlet pressure
mbar(a)
1050
psi
15.22
Maximum outlet pressure mbar(a) (vacuum pump)
mbar(a)
1013
psi
14.7
Maximum outlet pressure mbar(g) (overpressure pump)
bar(g)
2.5
psi
36.3
8.2 Pump data
Note: The readings below are valid when operating at reference conditions. See section Reference
conditions.
Common pump data
Unit
Number of compressions:
1
Maximum exhaust back pressure:
mbar(a)
1013
Torr
759.81
Temperature of the air leaving the discharge (Approx.)
°C
250
°F
482

Table of Contents

Related product manuals