6996 0223 96 Issue A
© Edwards Limited 2016. All rights reserved. Page 29
Edwards and the Edwards logo are trademarks of Edwards Limited.
CAUTION
Use an eye bolt provided at the pump for lifting the pump assembly. Do not use an eyebolt at the motor!
Always check the center of gravity while lifting the pump. Note that on some pressure pumps, the
weight of the motor is significant and may cause the pump to lift at an angle.
WARNING
It is not allowed to lift the pump if the canopy parts or lifting supports are not
completely installed.
When the pump is being lifted, it is also forbidden to come under the load or to
perform maintenance activities to it..
Acclimatization
Note: When moving the pump into an installation room, forming of condense can occur on some
components. To avoid dew harming of electrical components, ensure at least 2 hours of acclimatization
before switch on the pump.
3.3 Electrical connections
Always use a protection system, including an overcurrent protection and an electrical disconnecting device
between the pump and the electrical power supply. Refer the chapter “Motor data” in this book and motor
data plate for motor current details. The pump is delivered without electrical cable and switch. For the
electrical connection, check the diagram inside the terminal box or on the motor data plate.
WARNING
Before starting up the machine, check the rotation direction of the motor to prevent
pump failure. Motor rotation direction must be counter clockwise (when viewed from
Non-drive side to drive side) for all motor.
If this is incorrect, switch off the voltage and reverse two incoming electric lines.
WARNING
For the selection of the correct cables and fuses, refer to section “Electric cable size
and fuses” in this manual.