EFKA DA82GA3312
51
Functions Parameter
Speed stage graduation (nSt) 119
The pedal characteristics (speed change from stage to stage) can be varied.
Possible characteristic curves: - linear
- progressive
- highly progressive
6.33 Acoustic Signal
Functions Parameter
Acoustic signal when machine run blockage or thread monitor is On (AkS) 127
An acoustic signal which sounds in the following cases can be enabled using parameter 127:
Parameter 127 = 0 Acoustic signal Off.
Parameter 127 = 1 Acoustic signal from stop after execution of the stitches to pressing key 8.
Parameter 127 = 2 The drive stops after execution of the stitches. Sewing is possible up to the seam end. Then
the acoustic signal sounds until key 8 is pressed.
Parameter 127 = 3 The drive stops after execution of the stitches, and the acoustic signal sounds 5 times. Sewing
is possible up to the seam end. Then the acoustic signal sounds until key 8 is pressed.
6.34 Master Reset
Recovery of factory settings.
Press the "P" key and turn power on
Input code number "190"
Press the "E" key
Parameter 100 appears on the display
Press the "E" key
The parameter value is shown on the display
Set to "170" using the “+” key
Press the "P" key twice
Turn power off
Turn power on. All parameters, except 111, 161, 170, 171, 190...194, have been reset to their factory settings.